DC Characteristics :
(Ta = 0 to 70°C, VCC = + 3.3V ±10 %, VSS = 0V)
Parameter
Symbol
Test Conditions
Operating current
Low
power
S-version
Standby
Current
Standard
power
version
RAS- only refresh current
EDO page mode current
CAS- before- RAS refresh
current
Self- refresh current
(S-Version)
ICC1 RAS cycling
CAS, cycling
tRC = min
ICC2 LVTTL interface
RAS, CAS = VIH
Dout = High-Z
CMOS interface
RAS, CAS ≥ VCC -0.2V
Dout = High-Z
LVTTL interface
RAS, CAS = VIH
Dout = High-Z
CMOS interface
RAS, CAS ≥ VCC -0.2V
Dout = High-Z
ICC3
RAS cycling, CAS = VIH
tRC = min
ICC4 tPC = min
ICC5
ICC8
tRC = min
RAS, CAS cycling
tRASS ≥ 100µs
AD404M42V
Unit Notes
-5
-6
Min Max Min Max
- 120
- 110 mA 1, 2
- 0.5
- 0.5 mA
- 0.15
- 0.15 mA
-
2
-
2 mA
- 0.5
- 0.5 mA
- 120
- 90
- 120
- 550
- 110 mA 1, 2
- 80 mA 1, 3
- 110 mA 1, 2
- 550 µA
Rev.1
Page 8