LMG-SSC12A64 Datasheet, PDF (7/9 Pages) List of Unclassifed Manufacturers – DOT MATRIX LIQUID CRYSTAL DISPLAY MODULE | |||
|
◁ |
13. Reliability Condition
TN Type
STN Type
Normal Temp. Wide Temp. Normal Temp. Wide Temp.
Viewing
Angle
Horizontal Ƶ
Vertical ƨ Ä
Operating Temperature
Storage Temperature
Ã30Ä
-10Äto 30Ä
-10 to 70Ä
-20 to 80Ä
Ã30Ä
-10Äto 30Ä
-25 to 80Ä
-35 to 90Ä
Ã30Ä
-10Äto 40Ä
0 to 50Ä
-20 to 70Ä
Ã30Ä
-10Äto 40Ä
*-20 to 70Ä
*-30 to 80Ä
High Temperature (Power Off)
240 Hours
@70Ä
240 Hours
@90Ä
240 Hours
@65Ä
240 Hours
@75Ä
Low Temperature (Power Off)
240 Hours
@-20Ä
240 Hours
@-35Ä
240 Hours
@-15Ä
240 Hours
@-25Ä
High Temperature (Power On)
240 Hours
@70Ä
240 Hours
@80Ä
240 Hours
@60Ä
240 Hours
@70Ä
Low Temperature (Power On)
240 Hours
@-10Ä
240 Hours
@-25Ä
240 Hours
@-10Ä
240 Hours
@-20Ä
High Temperature & High
55Ä/90%RH
Humidity
240 Hours
Thermal Shock
C
A 60min@-20Ä
5 Cycle
B
A
B 5min@25Ä
C 60min@70Ä
75Ä/90%RH
240 Hours
60min@-35Ä
5min@25Ä
60min@90Ä
45Ä/90%RH
240 Hours
60min@-20Ä
5min@25Ä
60min@70Ä
65Ä/90%RH
240 Hours
60min@-30Ä
5min@25Ä
60min@80Ä
Expected Lift
50,000 Hours 50,000 Hours 50,000 Hours 50,000 Hours
*Wide temp. version may not available for some products, Please consult our sales engineer or respresentative.
14. Functional Test & Inspection Criteria
14.1 Sample plan
Sample plan according to MIL-STD-105D level 2, and acceptance/rejection criteria is.
Base on :
Major defect : AQL 0.65 Minor defect : AQL 2.5
14.2 Inspection condition
Viewing distance for cosmetic inspection is 30cm with bare eyes, and under an environment of
800 lus (20W) light intensity. All direction for inspecting the sample should be within 45Ä
against perpendicular line.
14.3 Definition of Inspection Zone in LCD
C
A
B
Zone A : Character / Digit area
Zone B : Viewing area except Zone A ( Zone A + Zone B = minimum Viewing area )
Zone C : Outside viewing area ( invisible area after assembly in customerâs product )
Note : As a general rule, visual defects in Zone C are permissible, when it is no trouble for
quality and assembly of customerâs product.
14.4 Major Defect
All functional defects such as open ( or missing segment ), short, contrast differential, excess
power consumption, smearing, leakage, etc. and overall outline dimension beyond the drawing.
Are classified as major defects.
14.5 Minor Defect
PAGE 6 (LMG-SSC12A64 Serial)
|
▷ |