English
Language : 

G3TB Datasheet, PDF (6/6 Pages) List of Unclassifed Manufacturers – Solid-state Relay
G3TB
G3TB
Precautions
Refer to pages 5 to 13 for general precautions.
Mounting
The rated values shown in this data sheet are standard values at an
ambient temperature of 40%C.
PWB
Soldering must be finished within 5 s at a temperature of 250%C.
Close Mounting (G3TB)
Take heat radiation into consideration when mounting.
The distance between adjacent SSRs must be 5 mm minimum.
G3TB
I/O classification by the color is as follows:
AC equipment
100 to 240 VAC
G3TB-IAZR02P
AC input module
Yellow
5 to 24 VDC
DC equipment
5 to 24 VAC
G3TB-IDZR02P
DC input module
White
5 to 24 VDC
AC equipment
100 to 240 VAC 3 A
G3TB-OA203PZ
G3TB-OA203PZM
G3TB-OA203PL
G3TB-OA203PLM
AC output module
Black
5 to 24 VDC
(4 to 24 VDC)
PC or logic circuitry
G3TB-ODX03P
Red
DC equipment
4 to 60 VDC/
40 to 200 VAC 3 A
G3TB-ODX03PM
G3TB-OD201P*
G3TB-OD201PM*
5 to 24 VDC
(4 to 24 VDC)
*With 1.5-A output.
DC output module
When mounting more than one output module, make a distance of 5
mm minimum between adjacent SSRs. Up to 16-point, 3-A load
switching is possible.
5 mm min.
Output module
DisALtrLiDbIMuEteNSdIObNyS :SHDOiWaNmAoREnIdN MEILleLIcMtErToEnRSic. s Ltd
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Tel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@diamondelec.co.uk
Web: www.diamondelec.co.uk
37