English
Language : 

EW162G0 Datasheet, PDF (6/12 Pages) List of Unclassifed Manufacturers – LCD DISPLAY MODULE
E M E R G I N G D I S P L A Y MODEL NO.
VERSION PAGE
TECHNOLOGIES CORPORATION 162G0(WHITE LED TYPES)(RoHS) 1
2
3 . ABSOLUTE MAXIMUM RATINGS
3 . 1 ELECTRICAL ABSOLUTE MAXIMUM RATINGS .
PARAMETER
POWER SUPPLY
FOR LOGIC
POWER SUPPLY
FOR LCD DRIVE
INPUT VOLTAGE
STATIC ELECTRICITY
LED POWER DISSIPATION
LED FORWARD CURRENT
LED REVERSE VOLTAGE
SYMBOL
VDD − VSS
VDD − VO
VI

PD
IF
VR
MIN .
0
0
VSS




MAX .
7.0
13.0
VDD
100
0.2
50
5
UNIT
V
V
V
V
W
mA
V
REMARK
NOTE ( 1 )
NOTE ( 1 ) : TEST METHOD AND CONDITIONS :
AFTER CHARGING UP 200 pF CAPACITOR BY STATED VOLTAGE ,
THE CAPACITOR IS CONNECTED WITH INTERFACE PINS OF THE
MODULE .
3 . 2 ENVIRONMENTAL ABSOLUTE MAXIMUM RATINGS .
ITEM
AMBIENT TEMPERATURE
HUMIDITY
VIBRATION
SHOCK
CORROSIVE GAS
OPERATING
MIN .
MAX .
- 2 0°C
7 0 °C
NOTE ( 2 )
4 . 9 m /s2

(0.5G)
2 9 . 4 m /s2

(3G)
NOT ACCEPTABLE
STORAGE
MIN .
MAX .
REMARK
- 3 0 °C
8 0 °C
NOTE ( 1 ), ( 3 )
NOTE ( 2 )
WITHOUT
CONDENSATION
1 9 . 6 m /s2

(2G)
4 9 0 . 0 m /s2 XYZ

( 5 0 G ) DIRECTIONS
NOT ACCEPTABLE
NOTE ( 1 ) : BACKGROUND COLOR CHANGES SLIGHTLY DEPENDING ON AMBIENT
TEMPERATURE THIS PHENOMENON IS REVERSIBLE.
NOTE ( 2 ) : Ta ≤ 60°C : 90%RH (96HR MAX.)
Ta > 60°C : ABSOLUTE HUMIDITY MUST BE
LOWER THAN THE HUMIDITY OF 90%RH AT 60°C(96HR MAX.)
NOTE ( 3 ) : Ta AT -30°C: WILL BE < 48hrs
80°C: WILL BE < 168hrs
02101300-01-02