English
Language : 

IP178C_1 Datasheet, PDF (51/93 Pages) List of Unclassifed Manufacturers – 8 Port 10/100 Ethernet Integrated Switch
IP178C/IP178C LF/IP178CH/IP178CH LF
Datasheet
PHY MII ROM R/W
Description
Default
MII status register (address 01)
0 1.4
-- RO Remote fault
0
LH 1 = remote fault detected
0 = not remote fault detected
When read as logic 1, indicates that IP178C/IP178CH has
detected a remote fault condition. This bit is set until remote
fault condition gone and before reading the contents of the
register. This bit is cleared after IP178C/IP178CH reset.
0 1.3
-- RO Auto-Negotiation Ability
1
1 = Auto-Negotiation capable
0 = not Auto-Negotiation capable
When read as logic 1, indicates that IP178C/IP178CH has the
ability to perform Auto-Negotiation. The value of this bit will
depend on the external mode setting of IP178C/IP178CH
operation mode.
0 1.2
-- RO Link Status
0
LL 1 = Link Pass
0 = Link Fail
When read as logic 1, indicates that IP178C/IP178CH has
determined a valid link has been established. When read as
logic 0, indicates the link is not valid. This bit is cleared until a
valid link has been established and before reading the
contents of this registers.
0 1.1
-- RO Jabber Detect
0
LH 1 = jabber condition detected
0 = no jabber condition detected
When read as logic 1, indicates that IP178C/IP178CH has
detected a jabber condition. This bit is always 0 for 100 Mbps
operation and is cleared after IP178C/IP178CH reset. This bit
is set until jabber condition is cleared and reading the
contents of the register.
0 1.0
-- RO Extended capability
1
1 = Extended register capabilities
0 = No extended register capabilities
IP178C/IP178CH has extended register capabilities.
Copyright © 2004, IC Plus Corp.
51/93
June 21, 2007
IP178Cx-DS-R12