English
Language : 

TC2411 Datasheet, PDF (5/16 Pages) List of Unclassifed Manufacturers – 14-Bit, 1 GSPS Digital-to-Analog Converter with Standby Mode of Operation
Datasheet (Advance Information)
TC2411
TC2411 Thermal Characteristics
Normal Mode of Operation
Package
19X19 Cavity-down
BGA 96L
θJC (oC/W)
2.72
θJA (oC/W)
0 m/s
2m/s
3m/s
20.2
18.5
17.5
Note
Results based on FEA simulation
without heat sink.
• The DC power of the TC2411 is 1.8 W in normal mode of operation
• Maximum Junction Temperature is not to exceed 110oC.
• There is no need for an external heat sink if maximum ambient temperature is +70oC.
• An external heat sink is recommended for ambient temperatures in excess of +70oC to insure that the
junction temperature does not exceed 110oC maximum.
• Use of standby mode reduces the average power dissipation proportional to the normal mode / standby
mode duty cycle and allows a higher ambient temperature before a heat sink must be used to insure that
the junction temperature does not exceed 110oC maximum.
• In the above table, θJA is presented according to JEDEC JESD 51-2 (natural convection) and 51-6 (forced
convection). Thermal simulation assumes the package is mounted on the test board specified by JEDEC
JESD51-9 (101.6X114.3X1.6 mm, four layers).
Note:
θJC: Thermal resistance from junction to case.
θJA: Thermal resistance from junction to ambient.
Figure 2: Standby Mode Operational Truth Table
Control Signal Normal Mode
STDBY_P
L
STDBY_N
H
Standby Mode
H
L
Figure 3: Standby/Normal Mode Timing
STDBY_P
STDBY_N
Standby
Mode
Normal Mode
Standby
Mode
<5µS
<5µS
5
MKDSTC2411 Rev-