English
Language : 

SM532 Datasheet, PDF (5/14 Pages) List of Unclassifed Manufacturers – Low EMI Spectrum Spread Clock
+/+
YJGP VKOKPI KU ETKVKECN
Approved Product
SM532
Low EMI Sprectum Spread Clock
Timing Characteristics
Characteristic
Symbol
Min
Typ
Max Units
Output Rise Time Measured at 10% - 90% @ 5 VDC
tTLH
3.3
3.5
3.8
ns
Output Fall Time Measured at 10% - 90% @ 5 VDC
tTHL
2.1
2.3
2.5
ns
Output Rise Time Measured at 0.8V - 2.0V @ 5 VDC
tTLH
0.7
0.75
0.8
ns
Output Fall Time Measured at 0.8V - 2.0 V @ 5 VDC
tTHL
0.6
0.7
0.8
ns
Output Rise Time Measured at 10% - 90% @ 3.3 VDC
tTLH
4.8
5.0
5.4
ns
Output Fall Time Measured at 10% - 90% @ 3.3 VDC
tTHL
2.9
3.2
3.4
ns
Output Rise Time Measured at 0.8V - 2.0V @ 3.3 VDC
tTLH
1.6
1.75
1.9
ns
Output Fall Time Measured at 0.8V - 2.0 V @ 3.3 VDC
tTHL
1.1
1.3
1.5
ns
Output Duty Cycle
TsymF1
45
50
55
%
Peak-to Peak Jitter One Sigma (SSON = 1)
tj1s
-
250
500
ps
Measurements performed at VDD = 3.3V +/-5% and 5V +/-10%, TA = 0°C to 70°C, CL = 15pF, Fout = 50.0 MHz.
Table 4.
FREQUENCY SELECTION TABLE
The following table provides the necessary information for setting the control lines for proper operation of the
SM532 and for any frequency within its operating range. Note that the table includes operating frequencies at 3.3
and 5.0 VDC. The 3.3 VDC columns are lower in frequency than the 5.0 VDC operation due to the characteristics
of the VCO.
VDD = 5
Fin (Range)
(MHz)
MIN MAX
See
14
30
14
30
14
30
Volts
Fout/
Fin
X
Note
1
2
4
+/- 10%
Fout (Range)
(MHz)
MIN MAX
14
30
28
60
56 120
Multiplier
Settings
S1 S0
00
01
10
11
Input Range
Settings
R1 R0
X
X
0
1
0
1
0
1
VDD = 3.3
Fin (Range)
(MHz)
MIN MAX
See
14 22.5
14 22.5
14 22.5
Volts
Fout/
Fin
X
Note
1
2
4
+/- 5%
Fout (Range)
(MHz)
MIN MAX
14 22.5
28
45
56
90
30
60
0.5 15
30
011
0
25 45 0.5 12.5 22.5
30
60
1
30
60
101
0
25 45
1
25
45
30
60
2
60 120
111
0
25 45
2
50
90
60
120 0.25 15
30
011
1
50 90 0.25 12.5 22.5
60
120 0.5 30
60
101
1
50 90 0.5
25
45
60 120
1
60 120
111
1
50 90
1
50
90
Note: Selects Power Down state, see table 7. X = don’t care condition.
Table 5. Frequency Selection Table
International Microcircuits,Inc.
525 Los Coches St., Milpitas, 95035 408-263-6300, FAX 408-263-6571
http:/www.imicorp.com
8/31/98
Rev. 1.4
Page 5 of 14