SED1190 Datasheet, PDF (5/8 Pages) List of Unclassifed Manufacturers – CMOS LCD 64-COMMON DRIVERS | |||
|
◁ |
SED1190
⢠DC Characteristics
(VDD = 0V, VSS = â5.0 V ±10%, Ta = â20 to 75°C)
Parameter
Supply voltage (1)
Supply voltage (2)
High level input voltage
Low level input voltage
High level output voltage
Low level output voltage
Input leakage current
Output leakage current
Shift clock
Frame signal
Input capacitance
Common output on
resistance
Quiescent current
Symbol
VSS
V1
V4
VSSH
VIH
VIL
VOH
VOL
ILI
ILO
YSCL
FR
CI
RCOM
IQ
Conditions
Rating
Min Typ Max
â5.5 â5.0 â4.5
VSSH
â
VDD
VSSH
â
VDD
Recommended VSSH
â25.0 â â14.0
Operable VSSH (see note)
â25.0 â â5.0
0.2VSS â VDD+0.3
VSSâ0.3 â 0.8VSS
IOH = â0.6 mA
â0.4 â
â
IOL = 0.6 mA
â
â VSS+0.4
0 V ⥠VI ⥠VSS
â 0.05 2.0
0 V ⥠VO ⥠VSS
â 0.05 5.0
â
â
2.5
â 1/60 â
Ta = 25°C
â
5.0 8.0
VOH = VDD â0.5 V VSSH = â20.0 V â
VOL = VSSH +0.5 V VSSH = â14.0 V â
COM bit
VSSH = â9.0 V â
0.8 1.0
0.9 1.3
1.3 2.0
VSSH = â5.0 V â
3.0 30.0
SED VSSH = â25 V, VSSH = â5.5 V, â
0.05
30
1190 VI = VDD
Unit
V
V
V
V
V
V
V
V
V
µA
µA
MHz
s
pF
kâ¦
µA
VSS = â5.0 V,
VIH = VDD,
VIL = VSS,
YSCL cycle =
Operating current for
ISS FR cycle = 16.7 ms 130 µs
â
3.0
8.0
µA
the logic
(duty 50%), All
âHâ output
terminals are
opened at every
data input all
1/128 duty.
VSS = â4.5 V,
V1 = â2.0 V,
V4 = â18.0 V,
YSCL cycle =
Operating current for LCD ISSH FR cycle = 16.7 ms 130 µs
â
3.0
8.0
µA
(duty 50%), All
âHâ output
terminals are
opened at every
data input of
1/128 duty.
Pull up MOS current
âIp
VSS = â5.0 V, VIL = â5.0 V
Applicable to LAT input terminals
10.0 25.0 50.0 µA
Note: Error free operation is guaranteed in this range but the output resistance of the LCD drivers is higher than in the recommended
operating range. It is suggested that the driver is tested with the target LCD panel to determine if performance is acceptable.
709
|
▷ |