English
Language : 

SED1190 Datasheet, PDF (5/8 Pages) List of Unclassifed Manufacturers – CMOS LCD 64-COMMON DRIVERS
SED1190
• DC Characteristics
(VDD = 0V, VSS = –5.0 V ±10%, Ta = –20 to 75°C)
Parameter
Supply voltage (1)
Supply voltage (2)
High level input voltage
Low level input voltage
High level output voltage
Low level output voltage
Input leakage current
Output leakage current
Shift clock
Frame signal
Input capacitance
Common output on
resistance
Quiescent current
Symbol
VSS
V1
V4
VSSH
VIH
VIL
VOH
VOL
ILI
ILO
YSCL
FR
CI
RCOM
IQ
Conditions
Rating
Min Typ Max
–5.5 –5.0 –4.5
VSSH
—
VDD
VSSH
—
VDD
Recommended VSSH
–25.0 — –14.0
Operable VSSH (see note)
–25.0 — –5.0
0.2VSS — VDD+0.3
VSS–0.3 — 0.8VSS
IOH = –0.6 mA
–0.4 —
—
IOL = 0.6 mA
—
— VSS+0.4
0 V ≥ VI ≥ VSS
— 0.05 2.0
0 V ≥ VO ≥ VSS
— 0.05 5.0
—
—
2.5
— 1/60 —
Ta = 25°C
—
5.0 8.0
VOH = VDD –0.5 V VSSH = –20.0 V —
VOL = VSSH +0.5 V VSSH = –14.0 V —
COM bit
VSSH = –9.0 V —
0.8 1.0
0.9 1.3
1.3 2.0
VSSH = –5.0 V —
3.0 30.0
SED VSSH = –25 V, VSSH = –5.5 V, —
0.05
30
1190 VI = VDD
Unit
V
V
V
V
V
V
V
V
V
µA
µA
MHz
s
pF
kΩ
µA
VSS = –5.0 V,
VIH = VDD,
VIL = VSS,
YSCL cycle =
Operating current for
ISS FR cycle = 16.7 ms 130 µs
—
3.0
8.0
µA
the logic
(duty 50%), All
“H” output
terminals are
opened at every
data input all
1/128 duty.
VSS = –4.5 V,
V1 = –2.0 V,
V4 = –18.0 V,
YSCL cycle =
Operating current for LCD ISSH FR cycle = 16.7 ms 130 µs
—
3.0
8.0
µA
(duty 50%), All
“H” output
terminals are
opened at every
data input of
1/128 duty.
Pull up MOS current
–Ip
VSS = –5.0 V, VIL = –5.0 V
Applicable to LAT input terminals
10.0 25.0 50.0 µA
Note: Error free operation is guaranteed in this range but the output resistance of the LCD drivers is higher than in the recommended
operating range. It is suggested that the driver is tested with the target LCD panel to determine if performance is acceptable.
709