English
Language : 

RUE090 Datasheet, PDF (5/11 Pages) List of Unclassifed Manufacturers – RUE090
5. Verify ambient operating conditions.
RUE
Radial Leaded
Ensure that your application’s minimum and maximum ambient
temperatures are within the operating temperature range of –40°C
and 85°C.
Maximum device surface temperature in the tripped state is 125°C.
6. Verify the RUE device’s dimensions.
Using dimensions from the table below, compare the dimensions of the
RUE device you selected with the application’s space considerations.
Product dimensions (millimeters/inches)
Part
A
B
C
D
E
F
number
max.
max.
typ.
min.
max.
typ.
RUE090
7.4 (0.29) 12.2 (0.48) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 0.8 (0.03)
RUE110
7.4 (0.29) 14.2 (0.56) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 0.8 (0.03)
RUE135
RUE160
8.9 (0.35) 13.5 (0.53)
8.9 (0.35) 15.2 (0.60)
5.1 (0.20) 7.6 (0.30) 3.0 (0.12)
5.1 (0.20) 7.6 (0.30) 3.0 (0.12)
0.8 (0.03)
0.8 (0.03)
4
RUE185 10.2 (0.40) 15.7 (0.62) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 0.8 (0.03)
RUE250 11.4 (0.45) 18.3 (0.72) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 0.8 (0.03)
RUE300 11.4 (0.45) 17.3 (0.68) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE400 14.0 (0.55) 20.1 (0.79) 5.1 (0.20) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE500 14.0 (0.55) 24.9 (0.98) 10.2 (0.40) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE600 16.5 (0.65) 24.9 (0.98) 10.2 (0.40) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE700 19.1 (0.75) 26.7 (1.05) 10.2 (0.40) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE800 21.6 (0.85) 29.2 (1.15) 10.2 (0.40) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
RUE900 24.1 (0.95) 29.7 (1.17) 10.2 (0.40) 7.6 (0.30) 3.0 (0.12) 1.2 (0.05)
Lead size
RUE090–RUE250
Ø 0.51
(0.020)
24 AWG
RUE300–RUE900 Ø 0.81
(0.032)
20 AWG
* Straight leads are available
** Kinked leads are available
RUE090–RUE250*
A
E
Marking
B
D
C
CL
CL
F
CL CL
RUE300–RUE900**
A
E
Marking
B
D
C
CL
CL
F
CL CL
Raychem Circuit Protection Devices
RUE Devices 145