English
Language : 

OTC-236 Datasheet, PDF (5/7 Pages) List of Unclassifed Manufacturers – THERMOPILE INFRARED SENSOR
▓ Order information : OTC-236-AB
A : 1 : standard filter (5-14 µm)
2 : silicon filter with flat band transmission
B : 1 : window size = 2.57mm (diameter)
2 : window size = 3.80mm (diameter)
▓ Transmission of filter
Transmission of optical filter is measured by FTIR from 2 µm
▓ Package
The sensor is hermetically sealed into a TO-5 metal housing, with an optical
filter. This standard filter allows measurements to be made in the spectral
range above 5 µm wavelength. The dimensions of header and cap are shown
below.