English
Language : 

GLT4160L04 Datasheet, PDF (5/22 Pages) List of Unclassifed Manufacturers – 4M X 4 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
G-LINK
GLT4160L04
4M X 4 CMOS DYNAMIC RAM WITH EXTENDED DATA OUTPUT
May 2001 (Rev.3.1)
DC and Operating Characteristics (1-2)
TA = 0°C to 70°C, -20°C to 85°C VCC=3.3V±0.3V, VSS=0V, unless otherwise specified.
Sym.
Parameter
ILI
Input Leakage Current
(any input pin)
ILO
Output Leakage Current
(for High-Z State)
ICC1 Operating Current,
Random READ/WRITE
ICC2 Standby Current (TTL)
ICC3
Refresh Current,
RAS -Only
ICC4 Operating Current,
EDO Page Mode
ICC5
Refresh Current,
CAS Before RAS
ICC6 Standby Current, (CMOS)
Test Conditions
0V ≤ VIN ≤ VCC+0.3V
(All other pins not under
test=0V)
0V ≤ Vout ≤ VCC
Output is disabled (Hiz)
tRC = tRC (min.)
RAS , CAS at VIH
other inputs ≥VSS
RAS cycling, CAS at VIH
tRC = tRC (min.)
RAS at VIL, CAS address
cycling:tPC=tPC(min.)
RAS , CAS address cycling:
tRC=tRC (min.)
RAS ≥VCC-0.2V,
Access
Time
tRAC = 40ns
tRAC = 50ns
tRAC = 60ns
tRAC = 70ns
tRAC = 40ns
tRAC = 50ns
tRAC = 60ns
tRAC = 70ns
tRAC = 40ns
tRAC = 50ns
tRAC = 60ns
tRAC = 70ns
tRAC = 40ns
tRAC = 50ns
tRAC = 60ns
tRAC = 70ns
Min. Typ
-5
-5
Max. Unit Notes
+5
µA
+5
µA
130
1,2
120
mA
80
70
1
mA
130
2
120
mA
80
70
130
1,2
120
mA
80
70
130
mA
1
120
80
70
CAS ≥VCC-0.2V,
All other inputs VSS
300
µA
1,5
ICC7 Self refresh Current
VIL
Input Low Voltage
VIH
Input High Voltage
VOL Output Low Voltage
VOH Output High Voltage
RAS = CAS =0.2V,
WE = OE = A0~A10=VCC-0.2V or
0.2V
DQ0~DQ3=VCC-0.2V,0.2V or
Open
IOL = 2mA
IOH = -2mA
300
µA
-0.3
+0.8
V
3
2.0
VCC+0.3
V
4
0.4
V
2.4
V
Notes:
1. ICC is dependent on output loading when the device output is selected. Specified ICC(max.) is measured with the output open.
2. ICC is dependent upon the number of address transitions specified ICC(max.) is measured with a maximum of one transition per address cycle
in random Read/Write and EDO Fast Page Mode.
3. Specified VIL(min.) is steady state operation. During transitions VIL(min.) may undershoot to –1V for a period not to exceed 15ns. All AC
parameters are measured with VIL(min.)≥VSS and VIH(max.)≤VCC.
4. Specified VIH(max.) is steady state operation . During transitions VIH(max.) may overshoot to VCC+1V for a period not to exceed 15ns. All AC
parameters are measured with VIL(min.) ≥ VSS and VIH(max.) ≤ VCC .
5. S-Version.
G-Link Technology
2701 Northwestern Parkway
Santa Clara, CA 95051, U.S.A.
-5-
G-Link Technology Corporation,Taiwan
6F, No. 24-2, Industry E. RD, IV, Science Based
Industrial Park, Hsin Chu, Taiwan.