IL3585 Datasheet, PDF (4/8 Pages) List of Unclassifed Manufacturers – PROFIBUS Compatible Isolated RS485 Interface
IL3585
Driver Section
Electrical Specifications are Tmin to Tmax unless otherwise stated.
Parameters
Symbol
Min.
Input Clamp Voltage
Output voltage
Differential Output Voltage(2)
Differential Output Voltage(2)
Differential Output Voltage(2)(6)
VIK
VO
|VOD1|
|VOD2|
2.5
VOD3
2.3
Change in Magnitude of Differential
Output Voltage(7)
∆|VOD|
Common Mode Output Voltage
VOC
Change in Magnitude of Common
Mode Output Voltage(7)
Output Current(4)
∆|VOC|
IO
Typ.(5)
3
High Level Input Current
Low Level Input Current
Absolute |Short-circuit Output Current|
Supply Current
(V DD2 = +5 V)
(V DD1 = +5 V)
(V DD1 = +3.3 V)
Parameters
Maximum Data Rate
Differential Output Prop Delay
Pulse Skew(10)
Differential Output Rise & Fall Time
Output Enable Time To High Level
Output Enable Time To Low Level
Output Disable Time From High Level
Output Disable Time From Low Level
Skew Limit(3)
IIH
IIL
IOS
IDD2
IDD1
IDD1
Symbol
tD(OD)
tS(P)
tT(OD)
tPZH
tPZL
tPHZ
tPLZ
tSK(LIM)
60
5
4
3
Switching Specifications
Min.
Typ.(5)
40
20
1
5
20
20
20
20
2
Max.
-1.5
VDD
VDD
5
5
±0.2
3
±0.2
1
-0.8
10
-10
250
8
6
4
Max.
30
6
8
30
30
30
30
12
Units
V
V
V
V
V
V
V
V
mA
µA
µA
µA
mA
Test Conditions
IL = -18 mA
IO = 0
IO = 0
RL = 54 Ω, VDD = 5 V
RL = 54 Ω, VDD = 4.5 V
RL = 54 Ω or 100 Ω
RL = 54 Ω or 100 Ω
RL = 54 Ω or 100 Ω
Output Disabled, VO = 12
VO = -7
V1 = 3.5 V
V1 = 0.4 V
-7 V> VO <12 V
No Load
(Outputs Enabled)
Units
Mbps
ns
ns
ns
ns
ns
ns
ns
ns
Test Conditions
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
RL = 54 Ω, CL = 50 pF
Notes: These apply to both driver and receiver sections
1. All Voltage values are with respect to network ground except differential I/O bus voltages.
2. Differential input/output voltage is measured at the noninverting terminal A with respect to the inverting terminal B.
3. Skew limit is the maximum propagation delay difference between any two devices at 25°C.
4. The power-off measurement in ANSI Standard EIA/TIA-422-B applies to disabled outputs only and is not applied to combined inputs and
outputs.
5. All typical values are at VDD1,VDD2 = 5 V or VDD1= 3.3 V and TA = 25°C.
6. While –7 V<VCM>12 V, the minimum VOD2 with a 54 Ω load is either ½ VOD1 or 2.3 V, whichever is greater.
7. ∆|VOD| and ∆ |VOC| are the changes in magnitude of VOD and VOC, respectively, that occur when the input is changed form one logic state to
the other.
8. This applies for both power on and power off, refer to ANSI standard RS-485 for exact condition. The EIA/TIA-422-B limit does not apply
for a combined driver and receiver terminal.
9. Includes 10 ns read enable time. Maximum propagation delay is 25 ns after read assertion.
10. Pulse skew is defined as the |tPLH –tPHL| of each channel.
11. Absolute Maximum specifications mean the device will not be damaged if operated under these conditions. It does not guarantee
performance.