English
Language : 

EMC12 Datasheet, PDF (31/48 Pages) List of Unclassifed Manufacturers – Audio Interface for the EmPack System
EMC12 Hardware Reference Manual
Table 1-19: AV9110 Serial Data Format
Bit(s)
0-6
7 - 13
14
15 - 16
17 - 18
19
20
21
22
23
Field
N
M
V
X
R
CLK_EN
CLK/X_EN
Reserved
CLK_SEL
Reserved
Function
VCO Frequency Divider
Reference Frequency Divider
VCO Pre-scale Divider
0b = divide by 1
1b = divide by 8
CLK/X Output Divider
00b = divide by 1
01b = divide by 2
10b = divide by 4
11b = divide by 8
VCO Output Divider
00b = divide by 1
01b = divide by 2
10b = divide by 4
11b = divide by 8
CLK Output Enable
0b = tristate
CLK/X Output Enable
0b = tristate
Should be 1
Reference clock select on CLK
1b = reference frequency
Should be 1
Default
1111111b
0010010b
0b
10b
10b
1b
1b
1b
0b
1b
The output frequency of CLK/X is given by:
fCLK/X = (fREF • N • V ) / (M • R • X)
where fREF is the input reference clock.
For a reference clock of 14.318MHz, Table 20 shows the bit stream associated with several commonly
used DSP clock frequencies. Note that CLK/X is multiplied by 4 to generate the DSP clock.
Table 1-20: Common AV9110 Data Stream
DSP Clock Frequency (MHz)
50
74
80
Bit Stream (Bit 23 - Bit 0)
0xB305CD
0xB304DD
0xB288DF
Refer to ICS AV9110 data sheet for more information on programming the device.
09 Jan 2006
Communication Automation Corporation
1-27