English
Language : 

THR-30185 Datasheet, PDF (3/4 Pages) List of Unclassifed Manufacturers – PRODUCT SPECIFICATION
MODEL: THR-30185
9/7/2004
CURRENT LIMIT INCEPTION @5V:
At .985Vout, 24V in, ± loads @ typical currents
DC-DC CONVERTER PRODUCT SPECIFICATIONS
3.50
3.70
4.10
A
100%
SHORT CIRCUIT CURRENT @5V:
Vo Recovery Test Only, 24 Vin
6
A
100%
DYNAMIC LOAD RESPONSE
RECOVERY TIME @5V:
5V load switched from 1.35A to 2.7A,±2% of Vo
150
300
µSec
100%
GENERAL:
MIN.
TYP.
MAX.
ISOLATION VOLTAGE:
750
1000
VDC
100%
ISOLATION RESISTANCE:
TBD
MOHM
GBD
ISOLATION CAPACITANCE:
500
pF
GBD
SWITCHING FREQUENCY:
150
165
180
KHZ
GBD
SYNC-ON/OFF CONTROL PIN:
PROVIDED, FUNCTION TESTED
MEETS REQUIREMENTS OF:
UL-1950
CSA-C22.2 No234
VDE
CALCULATED MTBF:
YES
YES
N/A
200,000
HOURS
GBD
GBD
GBD
MECHANICAL:
DIMENSIONS(NOMINAL):
WEIGHT (NOMINAL):
CASE MATERIAL:
EMI/RFI SHIELDING:
ENVIRONMENTAL:
OPERATING AMBIENT
TEMPERATURE Ta
WHERE NO DERATING REQUIRED:
Natural Convection,Vertical mount.
STORAGE TEMPERATURE
DERATING
MIN.
TYP.
MAX.
2" x 2" x .45"
INCHES
2
OUNCES
56
GRAM
BAKED ENAMEL STEEL,
NON CONDUCTIVE BASE
FIVE SIDED
MIN.
TYP.
MAX.
GBD
GBD
GBD
GBD
-25
55
°C
-55
125
°C
AS PER DERATING CURVE
GBD
GBD
GBD
DWG. No. 43869
REV.
A