English
Language : 

OM1805NMM Datasheet, PDF (3/4 Pages) List of Unclassifed Manufacturers – HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE REGULATORS APPROVED TO DESC DRAWINGS
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 12 Volt VIN = 19V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
VIN = 14.5V to 27V
11.88
12.12
V
•
11.64
12.36
V
IO = 5mA to 1.0 A, P < 15W
Line Regulation
(Note 1)
VRLINE
VIN = 14.5V to 27V
•
18
mV
50
mV
(Note 4)
VIN = 16V to 22V
•
9
mV
30
mV
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
IO = 5mA to 1.0 Amp
•
IO = 250mA to 750 mA
•
32
mV
60
mV
20
mV
40
mV
Standby Current Drain
ISCD
6.0
mA
•
6.5
mA
Standby Current Drain
∆ISCD
VIN = 15V to 30V
•
0.8
mA
Change With Line
(Line)
Standby Current Drain
∆ISCD
IO = 5mA to 1000mA
•
0.5
mA
Change With Load
(Load)
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 1.0A
•
2.5
V
Peak Output Current
IO (pk)
TA = 25°C
1.5
3.3
A
Short Circuit Current
IDS
(Note 2)
VIN = 35V
•
1.2
A
2.8
A
Ripple Rejection
Output Noise Voltage
(Note 3)
∆VIN
∆VOUT
NO
f =120 Hz, ∆VIN = 10V
(Note 3)
61
•
54
TA = 25°C, f =10 Hz to 100KHz
dB
dB
40
µV/V
RMS
Long Term Stability
(Note 3)
∆VOUT
∆t
TA = 25°C, t = 1000 hrs.
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
.140
.140
.140
.015
.075
1
2
.157
3
.415
.075
.030
MIN.
CONNECTION
Pin 1 Input
Pin 2 Output
Pin 3 Ground
3.5
.062
.375
3.5 - 39