English
Language : 

G2RS Datasheet, PDF (3/11 Pages) List of Unclassifed Manufacturers – General-purpose Relay
G2RS
G2RS
Contact Ratings
Plug-in Terminal Relays
Number of poles
Load
Rated load
Rated carry current
Max. operating voltage
Max. operating current
Max. switching
capacity
1 pole
Resistive load
(cosφ = 1)
10 (1) A at 250 VAC;
10 (1) A at 30 VDC
10 (1) A
380 VAC, 125 VDC
10 (1) A
2,500 (250) VA,
300 (30) W
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
2 poles
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1,250 VA,
150 W
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
Min. permissible load 100 mA at 5 VDC (1 mA at 5 VDC)
Note: 1. P level: λ60 = 0.1 x 10-6/operation
2. ( ): Twin crossbar contact type.
Characteristics
Standard Relays
10 mA at 5 VDC
Item
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
1 pole
2 poles
30 mΩ max.
50 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 when energized (approx. 20G); 100 m/s2 when no energized (approx. 10G)
Life expectancy
Ambient temperature
Ambient humidity
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Operating: –40°C to 70°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Operating: 35% to 85%
Storage: 35% to 85%
Weight
Approx. 17 g (plug-in terminal: approx. 20 g)
Note: Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
4