AHF2800 Datasheet, PDF (3/14 Pages) List of Unclassifed Manufacturers – Hybrid - High Reliability DC/DC Converters
TABLE II. Electrical Performance Characteristics - Continued
AHF2812S
Test
Symbol
Conditions
-55°C ≤ TC ≤ +125°C
VIN = 28 V dc ±5%, CL = 0 unless
otherwise specified
Output response to step
VOTLOAD
transient load changes 6/
500 mA to/from 1000 mA
0 mA to/from 500 mA
Recovery time, step
transient load changes
6/ 7/
TTLOAD
Output response to
VOTLINE
transient step line changes
Recovery time transient
step line changes
TTLINE
Turn on overshoot
VTonOS
Turn on delay
TonD
Load fault recovery 4/ 9/ TrLF
Weight
500 mA to/from 1000 mA
0 mA to 500 mA
500 mA to 0 mA
Input step 16 V to/from
40 V dc, IOUT = 1000 mA 4/ 8/
Input step 16 V to/from 40 V dc
IOUT = 1000 mA 4/ 7/ 8/
IOUT = 0 and 1000 mA
IOUT = 0 and 1000 mA 9/
Group A Device
Subgroups types
4
01
5,6
4
5,6
4,5,6
01
4,5,6
01
4,5,6
4,5,6
01
4,5,6
01
4,5,6
01
4,5,6
01
4,5,6
01
Limits
Unit
Min
-300
-450
-500
-750
Max
+300 mV pk
+450
+500
+750
100 µs
1500
10 ms
1500 mV pk
800 µs
600 mV pk
20 ms
20 ms
35 grams
Notes:
1/ Parameter guaranteed by line and load regulation tests.
2/ Bandwidth guaranteed by design. Tested for 20 kHz to 2 MHz.
3/ Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum
limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on.
4/ Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the
limits specified in Table II.
5/ An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the
condition of maximum power dissipation.
6/ Load step transition time between 2 and 10 microseconds.
7/ Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50 percent load.
8/ Input step transition time between 2 and 10 microseconds.
9/ Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 1)
while power is applied to the input is unlimited.
3