GV2P07 Datasheet, PDF (20/50 Pages) List of Unclassifed Manufacturers – Accurate and reliable control of motors
Electronic protection relays for use
with PTC thermistor probes
0–800 A
TeSys
LT3, LT6
For use with contactor
Motor current
Basic reference, to be completed
LC1-D or LC1-F
No limit
LT3S
3-pole multifunction protection relays
Operational current
A
0.2–1. 1–5
5
LT6P0M005FM
Protection units with automatic reset with thermistor short-circuit detection
■ without fault memory
Connection
Voltage
by cage connectors
AC 50/60 Hz
115 V
230 V
DC
24 V
On front panel: fault and voltage signalling indicator
AC 50/60 Hz
115/230 V
DC
24/48 V
AC 50/60 Hz or DC
24–230 V
■ with fault memory
On front panel: fault and voltage signalling indicator, Test and Reset button
AC 50/60 Hz
400 V
24/48 V
115/230 V
DC
24/48 V
AC 50/60 Hz or DC
24–230 V
Output contact
N.C.
N.C.
N.C.
N.C. + N.O.
N.C. + N.O.
2 C.O.
N.C. + N.O.
N.C. + N.O.
N.C. + N.O.
N.C. + N.O.
2 C.O.
Catalog number
LT3SE00F
LT3SE00M
LT3SE00F
LT3SA00M
LT3SA00ED
LT3SA00MW
LT3SM00V
LT3SM00E
LT3SM00M
LT3SM00ED
LT3SM00MW
For other versions, please consult with your local Schneider Electric/
Square D sales office: visit www.us.telemanique.com.
LT3
LT6
5/19