English
Language : 

V100 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Power Vector Modular Amplifiers
Technical
Specifications
Power Output (RMS): V35 V60 V100 V150 V250
Rated:
35W 60W 100W 150W 250W
Typical @ 1 kHz:*
45W 85W 140W 200W 340W
Frequency Response
Transformer:
45-20 kHz; 0/-2 dB
Direct:
20-20 kHz; 0/-1 dB
Distortion
Transformer:
0.5%**
Direct:
0.1%** (.05 typical @ 1 kHz)
Signal-to-Noise†
Fundamental:
-94 dB
With Aux Module:
-70 dB
With Mic Module:
-60 dB
With Tel Module:
-70 dB
Tone Controls
Bass Frequency:
100 Hz (+/- 10 dB minimum)
Treble Frequency:
10 kHz (+/- 10 dB minimum)
Low Cut Frequency:
125 Hz @ -6 dB/octave
Sensitivity
0.4V (at module bay connector)
Output Regulation: 2 dB or better, no load to full load
Output Impedance
Transformer-Coupled:
Direct Coupled:
Inserts
Insert "OUT" Level:
Insert "OUT" Impedance:
Insert "IN" Sensitivity:
Insert "IN" Impedance:
Pre-EQ Output
Output Level:
Output Impedance:
AC Power Receptacle:
AC Voltage:
AC Current:
Product Weight (lb.):
Dimensions:
70V, 25V, 8 ohms (bal or unbal)
4 ohms
1VRMS (@FRP)
50 ohms maximum
1VRMS
10k ohms minimum
4VRMS (@FRP)
50 ohms maximum
500 watts maximum power, unswitched
120V AC, 60Hz
V35 V60 V100 V150 V250
0.6A 1.3A 2.0A 3.5A 5.5A
V35 V60 V100 V150 V250
24 28 32 35 40
16-1/2" W x 3-1/2" H x 12" D
(all models)
Architect and
Engineer
Specifications
The amplifier shall be a Bogen Power Vector Amplifier,
Model V35,V60,V100,V150 or V250. The amplifier shall be
compatible with both high- (70/25V) and low- (4/8-ohm)
impedance speakers, with the capability of 35, 60, 100, 150,
or 250 watts, respectively.
The amplifier shall provide 8 module bays for plug-in input
modules with two of the bays also capable of handling plug-
in signal processing output modules.There shall be 4 levels
of priority between modules.
Each of the 8 module bays shall have an associated inde-
pendent volume control. Each independent volume control
shall have a signal/clip LED to indicate if a clipping condition
is occuring. Each amplifier shall also include bass and treble
controls, as well as a motorized master volume control,
which can be remotely operated using the RVCP accesso-
ry (sold separately).
Two screw terminals shall be provided for invoking a mas-
ter mute function that will interrupt all audio from the
mixer section of the Power Vector amplifier.
An 11-segment LED output level meter will register either
the average or peak level of the amplifier’s output level,
determined by an Average/Peak switch. Each Power Vector
amplifier shall have a Tone Control Bypass switch and a
Low-Cut Filter switch located on the rear of the amplifier
in module bay 6.
A lockable switch will permit the selection of transformer-
coupled output or direct output for speaker runs. Master
mute and remote volume control functions are controlled
using a screw terminal.
Signal processing insert jacks (RCA connectors) will allow
external equipment to be inserted between the pre-amp
output and the power amp input.
Each model will have a Pre-EQ unbalanced (RCA jack)
buffer output whose signal is post all volume controls, tone
controls, and output module signal processing, but before
(pre-EQ) any external signal processing equipment con-
nected to the Signal Processing Insert jacks.
Each amplifier will include a 500W maximum, unswitched
AC power receptacle.
The amplifier shall fit into a 19" rack and fit in two rack
spaces. It shall allow the attachment of feet for tabletop
placement. Each model shall measure 17" W x 3-1/2" H
x 13-1/2" D. The V35 shall weigh 24 lb., the V60 - 28 lb., the
V100 - 32 lb., the V150 - 35 lb., and the V250 - 40 lb.
* Typical, @1 kHz/0.1% THD/4Ω)
** THD+N, Maximum, Full bandwidth @ FRP
† Referenced to FRP output level, 20-20 kHz bandwidth limited.
50 Spring Street, Ramsey, New Jersey 07446, U.S.A.
201-934-8500 FAX: 201-934-9832
Web Site: www.bogen.com