FLOW
UNIVERSAL FLOW TRANSMITTER
MODEL UFT-1
WIRING
Output Pulse Divider
Selection Jumper Pulse
(10 or 100) 100
Out
Pulse
Out +
Pulse
Out –
mA Signal
10
Out
XDCR
Signal In
XDCR
Sig In
24 VDC
Power
PWR Common
Transducer Power Option Jumper
(Leave on for Data Industrial flow sensors.
Remove for devices with their own power supply.)
(red) + Flow
Sensor
(black) –
+–
24 VDC
Power Supply
Totalize
+
– Power
Typical
Totalizer
Hookup
+ 4-20 mA
– Output
INSTALLATION AND CALIBRATION
The UFT-1 transmitter can be mounted in any position. The
optional watertight enclosure provides a watertight seal
against contaminants. While field calibration is not required
with the UFT-1, flow conversion must be accomplished at the
monitoring computer. The information below is provided for
making the conversion calculations.
FLOW RATE
Flow (gpm) = (mA measured - 4 mA) x Maximum gpm
16
Maximum gpm is the flow rate at 20 mA output on the trans-
mitter and must be specified at the time the UFT-1 is ordered
for proper calibration.
TOTALIZED FLOW
Totalized Gallons = (Flow Factor) x (Output Divider) x (Total
Pulses)
For totalized m3, multiply the above by 0.00379.
Output Divider = 10 or 100 depending on jumper-selection.
Flow factors per pulse are shown in the table at the right.
TABLE 1. FLOW FACTORS FOR DATA INDUSTRIAL
FLOW SENSORS
MODEL
PIPE SIZE
in (cm)
FLOW
GALLONS/PULSE
FACTOR JUMPER IN JUMPER IN
10 POSITION 100 POSITION
228PV-1.5
228PV-2
228B-2
228C-2
250B-0.5
250B-0.75
250B-1
250B-1.25
250B-1.5
220B-2.5
220B
220B
220B
220B
220B
220B
220B
220B
220B
220B
1-1/2 (3.81)
2 (5.08)
2 (5.08)
2 (5.08)
1/2 (1.27)
3/4 (1.91)
1 (2.54)
1-1/4 (3.18)
1-1/2 (3.81)
2-1/2 (6.35)
3 (7.62)
4 (10.16)
5 (12.7)
6 (15.24)
8 (20.32)
10 (25.40)
12 (30.48)
14 (35.56)
16 (40.64)
18 (45.72)
0.03118
0.04611
0.04579
0.04731
0.005646
0.007514
0.007015
0.01280
0.01780
0.03800
0.07280
0.1396
0.2457
0.3611
0.6710
1.080
1.630
1.944
2.502
3.158
0.3118
0.4611
0.4579
0.4731
0.05646
0.07514
0.07015
0.1280
0.1780
0.3800
0.7280
1.396
2.457
3.611
6.710
10.80
16.30
19.44
25.02
31.58
3.118
4.611
4.579
4.731
0.5646
0.7514
0.7015
1.280
1.780
3.800
7.280
13.96
24.57
36.11
67.10
108.0
163.0
194.4
250.2
315.8
Notes
1. Flow factors for a Model 225 and 226 are the same as Model 220.
*2. Flow factor for Model 228S is the same as 228C.
3. PV Series is sized for SCH 80 PVC pipe.
All other series are sized for SCH 40 black iron pipe.
ORDERING INFORMATION
MODEL
UFT-1
UFT-1A
UFT-1E
UFT-1AE
DESCRIPTION
Universal Flow Transmitter Pulse Output Only
Universal Flow Transmitter with Pulse and Calibrated 4-20 mA Output*
Universal Flow Transmitter Pulse Output in NEMA 4X Enclosure
Universal Flow Transmitter with Pulse and Calibrated 4-20 mA Output* in NEMA 4X Enclosure
DISPLAY OPTION (enclosed models only)
1 Flow totalization only
2 Flow rate only
3 Flow totalization and flow rate **
* Pipe size and schedule and
maximum flow rate must be
specified at time of order.
** When a UFT-1AE3 is ordered
the UFT-1A will be in one enclosure
and the Totalizer and Rate Display
will be in a separate enclosure.
UFT-1
1 Example: UFT-1A-E-2 Basic transmitter with calibrated 4-20 mA flow rate
output (4 mA = no flow 20 mA = max flow), enclosed with LCD
flow rate indication
224