English
Language : 

SP2402 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
Thermoelectric Cooler
SP2402
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
Hot Side Temperature: 50°C
Heat
120.0
110.0
100.0
90.0
80.0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
Load (W)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
130.0
120.0
110.0
100.0
90.0
80.0
70.0
60.0
50.0
40.0
30.0
20.0
10.0
0.0
11.00.0 1.0 2.0 3.0 4.0 5.0 6.0
12.00.0 1.0 2.0 3.0 4.0 5.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Q=0
∆T = 0
11.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
Q=0
∆T = 0
0.0
0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0
0.0 1.0 2.0 3.0 4.0 5.0
Current (amps)
Current (amps)
Heat
Load (W)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
6.0
6.0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To
minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
TEL: 214-340-4900
FAX: 214-341-5212
Internet: http://www.marlow.com
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
TEL: +44 (0)1444-443404
FAX: +44 (0)1444-443334
Marlow Industries Asia
1-1-8-401
Uehara, Shibuya-ku
Tokyo, Japan 151-0064
TEL: +81 (3) 5454-5280
FAX: +81 (3) 5454-5281
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0230, Rev 2