English
Language : 

SBF-5089 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – DC-500 MHz, Cascadable InGaP/GaAs HBT MMIC Amplifier
Preliminary
SBF-5089 DC-500 MHz Cascadable MMIC Amplifier
Typical RF Performance at Key Operating Frequencies
Symbol
Parameter
Unit
70
G Small Signal Gain
dB
20.5
OIP3 Output Third Order Intercept Point dBm
39
P1dB Output Power at 1dB Compression dBm 21.0
IRL Input Return Loss
dB
19.4
ORL Output Return Loss
dB
17.2
S12 Reverse Isolation
dB
25.2
NF Noise Figure
TeTsetstCCoonnddititioionnss:
RVVRSBSIB=AI=SAS8=8=3VV339OOhhmmss
dB
2.7
TIDTILD=L===92802505mººCmCAATTyypp..
FreFqrueqenuceync(My H(MzH) z)
100
240
400
500
850
20.4
20.1
19.8
19.5
18.2
39
41
39.5
39
34
21.0
21.0
20.7
20.8
18.6
19.9
20.1
20.9
22.0
26.8
15.8
18.6
24.0
37.5
15.5
22.4
22.3
22.3
22.3
22.4
2.8
2.7
2.8
2.8
2.8
ZOZOSISP=IP=3Z3TZLToL=on=ne55e0S0SpOOpaahhccmmininsgsg==u1s1MinMgHHzaz,p,pPPocouirutctpupeitersrteotoennepe=a=g0e0d4dBBmm
Absolute Maximum Ratings
21.5
21
20.5
20
19.5
19
18.5
18
17.5
50
P1dB vs Temp
+25c
-40c
+85c
150 250 350 450 550 650 750 850
Frequency(MHz)
43
41
39
37
35
33
31
29
27
25
50
TOIP vs Temp
+25c
-40c
+85c
150 250 350 450 550 650 750 850
Frequency(MHz)
Parameter
Absolute Limit
Max. Device Current (ID)
Max. Device Voltage (VD)
Max. RF Input Power
150 mA
6V
+19 dBm
Max Operating Dissipated
Power
0.8 W
Max. Junction Temp. (TJ)
Operating Temp. Range (TL)
Max. Storage Temp.
+150°C
-40°C to +85°C
+150°C
Operation of this device beyond any one of these limits may
cause permanent damage. For reliable continous operation,
the device voltage and current must not exceed the maximum
operating values specified in the table on page one.
Bias Conditions should also satisfy the following expression:
IDVD < (TJ - TL) / RTH, j-l
TL=TLEAD
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
50
Noise Figure vs Temp
+25c
-40c
+85c
150 250 350 450 550 650 750 850
Frequency(MHz)
303 South Technology Court, Broomfield, CO 80021
Phone: (800) SMI-MMIC
2
http://www.sirenza.com
EDS-103413 Rev. C