English
Language : 

SBA-5089 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – DC-5 GHz, Cascadable InGaP/GaAs HBT MMIC Amplifier
Preliminary
SBA-5089 DC-5 GHz Cascadable MMIC Amplifier
Typical RF Performance at Key Operating Frequencies
Symbol
Parameter
Unit
100
G Small Signal Gain
dB
20.5
OIP3 Output Third Order Intercept Point dBm 36.3
P1dB Output Power at 1dB Compression dBm
19.8
IRL Input Return Loss
dB
29
ORL Output Return Loss
dB
27
S21 Reverse Isolation
NF Noise Figure
TeTsetstCCoonnddititioionnss:
RVVRSBSIB=AI=SAS8=8=V3V399OOhhmmss
dB
22
dB
4.1
TIDTILD=L===82802505ºmCºmCAA TTyypp..
FreFqrueqenuceync(My H(MzH) z)
500
850
1950
2400
3500
20.2
19.9
18.0
17.1
15.3
35.8
36.0
34.0
32.7
30.9
19.8
19.7
19.5
18.8
17.1
27
25
20
17
11.8
21
17
11
11
11
22
23
23
23
23
4.3
4.2
4.5
----
----
ZOZOSISP=IP=3Z3TZLToL=on=n5e5e0S0SOpOphahamcmcinsinsgg==11MMHHzz, ,PPoouut tppeerrtotonnee==00ddBBmm
Absolute Maximum Ratings
Noise Figure vs. Frequency
6
5
4
3
+25c
-40c
+85c
2
0
0.5
1
1.5
2
Frequency (GHz)
OIP3 vs. Frequency
38
+25c
36
-40c
+85c
34
Parameter
Absolute Limit
Max. Device Current (ID)
Max. Device Voltage (VD)
Max. RF Input Power
130 mA
6V
+17 dBm
Max Operating Dissipated
Power
0.65 W
Max. Junction Temp. (TJ)
Operating Temp. Range (TL)
Max. Storage Temp.
+150°C
-40°C to +85°C
+150°C
Operation of this device beyond any one of these limits may
cause permanent damage. For reliable continous operation,
the device voltage and current must not exceed the maximum
operating values specified in the table on page one.
Bias Conditions should also satisfy the following expression:
IDVD < (TJ - TL) / RTH, j-l
TL=TLEAD
P1dB vs. Frequency
21
+25c
20
-40c
+85c
19
32
18
30
17
28
16
26
0 0.5 1 1.5 2 2.5 3 3.5
Frequency (GHz)
15
0 0.5 1 1.5 2 2.5 3 3.5
Frequency (GHz)
303 South Technology Ct., Broomfield, CO 80021 Phone: (800) SMI-MMIC
2
http://www.sirenza.com
EDS-102743 Rev. C