English
Language : 

MOC3080 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – OPTICALLY COUPLED BILATERAL SWITCH LIGHT ACTIVATED ZERO VOLTAGE CROSSING TRIAC
ELECTRICAL CHARACTERISTICS ( T = 25°C Unless otherwise noted )
A
PARAMETER
MIN TYP MAX UNITS
TEST CONDITION
Input
Output
Forward Voltage (V )
F
Reverse Current (IR)
Peak Off-state Current ( I )
DRM
Peak Blocking Voltage ( VDRM )
On-state Voltage ( VTM )
Critical rate of rise of
off-state Voltage ( dv/dt )
1.2 1.5 V
100 µA
300 nA
800
V
1.8 3.0 V
100
V/µs
I = 30mA
F
VR = 6V
V = 800V (note 1 )
DRM
I = 300nA
DRM
ITM = 100mA ( peak )
Coupled
Input Current to Trigger ( IFT )(note 2 )
MOC3080
MOC3081
MOC3082
MOC3083
30 mA
15 mA
10 mA
5 mA
VTM = 3V ( note 2 )
Zero
Crossing
Charact-
-eristic
Holding Current , either direction ( IH )
100
µA
Input to Output Isolation Voltage VISO 5300
VRMS
7500
V
PK
Inhibit Voltage ( VIH )
35 V
Leakage in Inhibited State ( I )
S
500 µA
See note 3
See note 3
IF= Rated IFT
MT1-MT2 Voltage
above which device
will not trigger
I = Rated I
F
FT
VDRM = 800V off-state
Note 1. Guaranteed to trigger at an I value less than or equal to max. I , recommended I lies
F
FT
F
between Rated I and absolute max. I .
FT
F
Note 2. Measured with input leads shorted together and output leads shorted together.
10/5/01
DB92698m-AAS/A1