English
Language : 

MOC3060 Datasheet, PDF (2/4 Pages) List of Unclassifed Manufacturers – OPTICALLY COUPLED BILATERAL SWITCH LIGHT ACTIVATED ZERO VOLTAGE CROSSING TRIAC
ELECTRICAL CHARACTERISTICS ( T = 25°C Unless otherwise noted )
A
PARAMETER
MIN TYP MAX UNITS
TEST CONDITION
Input
Output
Forward Voltage (V )
F
Reverse Current (IR)
Peak Off-state Current ( I )
DRM
Peak Blocking Voltage ( VDRM )
On-state Voltage ( VTM )
Critical rate of rise of
off-state Voltage ( dv/dt )
1.2 1.4 V
0.05 10 µA
500 nA
600
V
3.0 V
600 1500
V/µs
I = 20mA
F
VR = 6V
V = 600V (note 1 )
DRM
I = 500nA
DRM
ITM = 100mA ( peak )
Coupled
Input Current to Trigger ( IFT )(note 2 )
MOC3060
MOC3061
MOC3062
MOC3063
30 mA
15 mA
10 mA
5 mA
VTM = 3V ( note 2 )
Holding Current , either direction ( IH )
Input to Output Isolation Voltage VISO
400
5300
µA
VRMS
See note 3
Zero
Crossing
Charact-
-eristic
Inhibit Voltage ( VIH )
Leakage in Inhibited State ( I )
S
20 V
500 µA
IF= Rated IFT
MT1-MT2 Voltage
above which device
will not trigger
I = Rated I
F
FT
VDRM = 600V off-state
Note 1. Test voltage must be applied within dv/dt rating.
Note 2. Guaranteed to trigger at an I value less than or equal to max. I , recommended I lies
F
FT
F
between Rated IFT and absolute max. IF .
Note 3. Measured with input leads shorted together and output leads shorted together.
20/9/02
DB91051m-AAS/A7