HMC6052 SPECIFICATIONS
Characteristics
Conditions*
Supply Voltage
Vsupply, Vbridge to GND
Supply Current
Vsupply to GND
Bridge Current
A, B bridges
Field Range
Full scale (FS), Vsupply, Vbridge = 3.0 volts
Field Sensitivity
Vsupply, Vbridge = 3.0 volts
Zero Field Output
Vsupply, Vbridge = 3.0 volts
Load Resistance
Applied to OUTA, OUTB
Load Capacitance
Applied to OUTA, OUTB
Bandwidth
system signal output (lower limit = DC)
Noise Floor
Vsupply, Vbridge = 3.0V
SINL, SINH toggle before measurement
Linearity
Vsupply, Vbridge=3.0V, Field +/- 0.5 Oe
Disturbing Field
Sensitivity starts to degrade.
Use set pulse to restore sensitivity.
Max. Exposed
No perming effect on zero field reading
Field
Operating
Ambient
Temperature
Storage
Ambient, Unbiased
Temperature
Sensitivity
Tempco
Output Voltage
Tempco
Sensitivity Ratio of
Sensors
TA= 0 to 70°C
X,Y sensor
Sensitive direction in X and Y sensors
Orthogonality
* Tested at 25°C except stated otherwise.
Min
2.5
-2.0
6000
-
1
20
-45
-55
-3000
95
Typ
3.0
6
0.5
1.5
10,000
1
0.4
-2700
± 500
100
Max
3.6
9
+2.0
-
100
10000
120
150
-2400
105
0.01
Units
Volts
mA
mA
gauss
V/gauss
volts
ohms
pF
kHz
mV
%FS
Gauss
Gauss
°C
°C
ppm/°C
ppm/°C
%
Degree
Characteristics
Conditions*
Set Strap Circuit
Input Logic Voltage Measured from SIN to GND (Vsupply = 3.0v)
Low “0” State
High “1” State
Input Logic Current
Offset Straps
Resistance
Measured from OFF+ to OFF-
Offset
DC Current
Constant
Field applied in sensitive directions
Resistance
Tempco
* Tested at 25°C except stated otherwise.
TA= 0 to 70°C
2
Min
12
3500
Typ
0.3
2.5
0
15
10
3900
Max
Units
volts
volts
µA
18
ohms
mA/gauss
4300 ppm/°C
www.honeywell.com