English
Language : 

COM7905T Datasheet, PDF (2/4 Pages) List of Unclassifed Manufacturers – COMMERCIAL OFF-THE-SHELF FIXED VOLTAGE NEGATIVE REGULATORS IN TO-257
COM7900T Series
3.3
ELECTRICAL CHARACTERISTICS -5 Volt VIN = -10V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
Line Regulation
(Note 1)
VO U T
VRLINE
TA = 25°C
VIN = -7.5V to -20V
VIN = -7.5V to -20V
-4.9
-5.1
V
•
-4.8
-5.2
V
12
mV
•
25
mV
VIN = -8.0V to -12V
•
5
mV
12
mV
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
•
20
mV
25
mV
IO = 250mA to 750 mA
•
15
mV
30
mV
Standby Current Drain
IS C D
2.5
mA
•
3.0
mA
Standby Current Drain
DIS C D
VIN = -7.0V to -20V
•
0.4
mA
Change With Line
(Line)
Standby Current Drain
DIS C D
IO = 5mA to 1000mA
•
0.4
mA
Change With Load
(Load)
Dropout Voltage
VD O
DVOUT = 100mV, IO = 1.0A
•
2.5
V
Peak Output Current
IO (pk)
TA = 25°C
1.5
3.3
A
Short Circuit Current
ID S
(Note 2)
VIN = -35V
•
1.2
A
2.8
A
Ripple Rejection
Output Noise Voltage
(Note 3)
DVIN
DVO U T
NO
f =120 Hz, DVIN = -10V
(Note 3)
TA = 25°C, f =10 Hz to 100KHz
63
•
60
dB
dB
40
µV/V
RMS
Long Term Stability
(Note 3)
DVO U T
Dt
TA = 25°C, t = 1000 hrs.
75
mV
ELECTRICAL CHARACTERISTICS -12 Volt VIN = -19V,Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
Line Regulation
(Note 1)
VOUT
VRLINE
TA = 25°C
VIN = -14.5V to -27V
VIN = -14.5V to -27V
-11.76
-12.24
V
•
-11.6
-12.4
V
20
mV
•
50
mV
VIN = -16V to -22V
•
10
mV
30
mV
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
•
32
mV
60
mV
IO = 250mA to 750 mA
•
16
mV
30
mV
Standby Current Drain
IS C D
3.5
mA
•
4.0
mA
Standby Current Drain
DIS C D
VIN = -14.5V to -27V
•
0.8
mA
Change With Line
(Line)
Standby Current Drain
DIS C D
IO = 5mA to 1000mA
•
0.5
mA
Change W ith Load
(Load)
Dropout Voltage
VD O
DVOUT = 100mV,IO = 1.0A
•
1.8
V
Peak Output Current
IO (pk)
TA = 25°C, IO = 5mA to 1A
1.5
3.3
A
Short Circuit Current
ID S
(Note 2)
VIN = -35V
•
1.2
A
2.8
A
Ripple Rejection
Output Noise Voltage
(Note 3)
DVIN
DVO U T
NO
f =120 Hz, DVIN = -10V
(Note 3)
TA = 25°C, f =10 Hz to 100KHz
56
•
53
dB
dB
40
µV/V
RMS
Long Term Stability
(Note 3)
DVO U T
Dt
TA = 25°C, t = 1000 hrs.
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.