English
Language : 

WP1602A-Y-JCS Datasheet, PDF (17/20 Pages) List of Unclassifed Manufacturers – WP1602A-Y-JCS
Power on
Wait for more than 15 ms after VCC rises to 4.5 V
BF can not be checked before this instruction.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 Function set ( Interface is 8 bits long. )
000011****
Wait for more than 4.1 ms
BF can not be checked before this instruction.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 Function set ( Interface is 8 bits long. )
000011****
Wait for more than 100 µs
BF can not be checked before this instruction.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 Function set ( Interface is 8 bits long. )
000011****
BF can be checked after the following instructions.
When BF is not checked , the waiting time between
instructions is longer than execution instruction time.
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0 0 0 0 1 1 NF * *
000000 1000
0000000001
0 0 0 0 0 0 0 1 I/D S
Function set ( Interface is 8 bits long. Specify
the number of display lines and font. )
The number of display lines and character font
can not be changed after this point.
Display off
Display clear
Entry mode set
Initialization ends
8-Bit Ineterface
第 17 頁,共 20 頁