English
Language : 

TDA4321XS Datasheet, PDF (13/16 Pages) List of Unclassifed Manufacturers – FM-IF IC with counter output, analog STS, field strength indicator, noise detector and mute setting
FS: 04/93
SIEMENS AG
Page 13
IC-SPECIFICATION
TDA 4321 XS
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Diagrams
VF Characteristic
D1
UF (V)
5
2.5
-80
M3
MVFmin
-60
-40
-20
0 UiIF (dBm)
M1
M2
M4
VF - Dynamic
MVFmax
VF - Dynamic :The dynamic range of VF voltage is determined by
the test points M1 through M4 as follows:
M1: test point (at ViIF= -60 dBm) supplies VF (M1)
M2: test point (at ViIF= -20 dBm) supplies VF (M2)
M3: test point (at ViIF= -90 dBm) supplies VF (M3)
M4: test point (at ViIF= +5 dBm) supplies VF (M4)
Hence follows :
UF (M4) - UF (M2)
MVFmax:= - 20 dBm+––––––––––––––––– × 40 dB
UF (M2) - UF (M1)
UF (M1) - UF (M3)
MVFmin:= - 60 dBm - ––––––––––––––––– × 40 dB
UF (M2) - UF (M1)
VF - Dynamic = MVFmax - MVFmin
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created
by patent grant or registration of a utility model or design, are reserved.
HL DOK
V66047-S1665-B100-G1
5.10.98