English
Language : 

NA1TR8 Datasheet, PDF (13/50 Pages) List of Unclassifed Manufacturers – nanoNET TRX Transceiver
4 Absolute Maximum Ratings
nanoNET TRX Transceiver (NA1TR8) Datasheet
4 Absolute Maximum Ratings
Parameter
Table 2: Absolute maximum ratings
Valuea
Units
Item
Maximum received power
-20
dBm
5.1
Temperatures
5.2
Operating temperature
(operating ambient temperature range)
+85
°C
5.3
Operating junction temperature
(operating junction temperature range in
TX mode)
+95
°C
5.4
Operating junction temperature
(operating junction temperature range in
RX mode)
+90
°C
5.5
Storage temperature
(storage temperature range)
+125
°C
5.6
Reflow solder temperature (lead-free package)
+242
°C
5.7
Total power dissipation
450
mW
5.8
Supply voltage (VDDA, VDDD)
3.6
V
5.9
a. It is critical that the ratings provided in Absolute Maximum Ratings be carefully observed. Stress exceeding
one or more of these limiting values may cause permanent damage to the device.
5 Nominal Conditions
Nominal conditions are as specified below, except
otherwise specified:
+ Reference design (for measurement purposes
only) has been used. See Reference Design on
page 33.
+ Tjunct = 30° C
+ VSSA = VSSD = GND
+ VDDA = VDDD = 3.0 V
+ Transmission/reception @ 1 Mbps and up/down
chirp mode.
+ Raw data mode: no CRC, no FEC, no encryp-
tion, no bit scrambling.
+ BER = 0.001 during receive period.
+ RF output power during transmit phase = 6.3
mW (+8 dBm) EIRP measured during continu-
ous transmission.
+ All RF ports are matched according to this spec-
ification.
+ For range measurement, two identical nanoNET
systems equipped with antennae representing
1.6 dBi gain have been used. Antennae with
vertical E-polarization and omnidirectional hori-
zontal radiation pattern have been used.
+ Outdoor (open space) range measurement was
performed on flat terrain, without vegetation
higher than 0.2 m above ground, and without
visible obstacles and other objects that could
reasonably influence measurement results.
Antennae for both nanoNET systems have been
located 1.5 m above ground.
+ Indoor range measurement was performed
inside typical European office building where
both nanoNET systems were located on the
same floor.
+ All RF powers (TX output power, RX sensitivity,
etc.) are measured on the IC terminals (pins)
under impedance matched conditions.
© 2007 Nanotron Technologies GmbH.
NA-03-0111-0239-2.09 Page 7