3.3 Clock and Reset Timing
To reset the AMBE-2000 chip, the reset signal must be held low for a minimum of six clock cycles. The recovery time from
reset is approximately 95 msec. In other words, 95 msec after the rising edge of the reset signal the AMBE-2000 starts
processing PCM samples. The first packet will be ready after 252 PCM samples are read.
Figure 3-A X2/CLKIN and CLKOUT Timing Diagram
X2/CLKIN
CLKOUT
tc(CI)
tw(CIH)
tw(CIL)
tr(CI)
tf(CI)
tp
Unstable
td(CIH-CO)
tc(CO)
tw(COH)
tf(CO)
tw(COL)
tr(CO)
Table 3-A X2/CLKIN and CLKOUT Timing Parameters
Reference
Parameter
Min
Max Units
tc(CI)
Cycle time,
X2/CLKIN
Integer PLL multiplier N (N=4)
20
400
ns
tf(CL)
Fall time, X2/CLKIN
4
ns
tr(CL)
Rise time, X2/CLKIN
4
ns
tw(CIL)
Pulse duration, X2/CLKIN low
6
ns
tw(CIH)
Pulse duration, X2/CLKIN high
6
ns
tp
Transitory phase, PLL lock-up time
50
µs
tc(CO)
Cycle time, CLKOUT (typical is tc(CI)/4
15
ns
td(CIH-CO) Delay time, X2/CLKIN high/low to CLKOUT high/low
4
16
ns
tf(CO)/tr(CO) Fall/Rise time, CLKOUT (typical is 2 ns)
Tw(COL)
Pulse duration, CLKOUT low
H-4
H
ns
Tw(COH)
Pulse duration, CLKOUT high
H-4
H
ns
•
CLKOUT is shown for reference only. It is not to be connected in the circuit.
•
H = 7.629 ns