8.3.1. I²C-bus sequence read
Start Slave addr. R/W =1 Ack data
Ack not Stop
Start
Slave addr
R/W
Ack
Ack not
Stop
start condition.
Slave address = 43[hex].
Read/Write bit: 0 = write to component; 1 = master reads from component.
acknowledge, generated by the component
acknowledge, generated by the master
stop condition
8.3.2 Read data format
Status register
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Power on reset
0 Normal
operation
1 Power on reset
AFC value
AFC4
AFC3
AFC2
AFC1
CARRDET – FM carrier detection
0
FM carrier not detected
1
FM carrier detected
VIFLEV - VIF level input
0
VIF low level
1
VIF high level
AFCWIN - AFC window (Note 1)
0
Tuning out of window (+/- 1.6 MHz)
1
Tuning in window (+/- 1.6 MHz)
Note1. If no IF input is applied, then bit AFCWIN = 1 due to the fact that the VCO is forced to the AFC window border for
fast load-in behaviour.
Automatic Frequency Control fVIF Versus f0
fVIF ≤ f0 – 187.5 kHz
fVIF = f0 – 162.5 kHz
fVIF = f0 – 137.5 kHz
fVIF = f0 – 112.5 kHz
fVIF = f0 – 87.5 kHz
fVIF = f0 – 62.5 kHz
fVIF = f0 – 37.5 kHz
fVIF = f0 – 12.5 kHz
fVIF = f0 + 12.5 kHz
fVIF = f0 + 37.5 kHz
fVIF = f0 + 62.5 kHz
fVIF = f0 + 87.5 kHz
fVIF = f0 + 112.5 kHz
fVIF = f0 + 137.5 kHz
fVIF = f0 + 162.5 kHz
fVIF ≥ f0 + 187.5 kHz
AFC4
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
AFC3
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
AFC2
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
AFC1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
3X8168 ED