Table 4. PNB_TNB Bit Definition;
# of Pressure Gaps 4MSB of PNB_TNB Value
Fixed
15 (F hex)
1
14 (E hex)
2
12 (C hex)
3
10 (A hex)
4
8
5
6
Table 5. PNB_TNB Bit Definition;
Temperature Gaps
# of Temperature Gaps
Fixed (1)
2 Gaps
3 Gaps
4 Gaps
4 LSB of PNB_TNB
0
5
8
11 (B hex)
MLX90314AB
Programmable Sensor Interface
Table 6. Temperature
Maximum number of
temperature gaps
Fixed Gain and
fixed Offset
2 Gaps
3 Gaps
4 Gaps
Maximum number of
signal gaps
5 Gaps
3 Gaps
2 Gaps
Fixed signal
Figure 3. Temperature
Linearity Correction
OF & GN
MLX90314
OFTC4
OFTC3
OFTC2
OFTC1
GNTC3
GNTC4
OF0
GNTC2
i4
GN0 GNTC1
i3
i2
i1
1 Gap
0
T1
T2
T3
3FFh
Baseline Calibration
MLX90314AB Programmable Sensor Interface
Figure 4. Signal
Linearity Correction
Output
MLX90314
PC5
PC4
PC3
PC2
PC1
0
P2 P3 P4 P5
Page 12
Rev 2.2