English
Language : 

VRE105 Datasheet, PDF (1/5 Pages) List of Unclassifed Manufacturers – Precision Reference Supplies
VRE105/107
Precision
Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
APPLICATIONS
• VERY HIGH ACCURACY: 5.000 V ±0.4 mV
• EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C
• EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
• EXCELLENT LINE REGULATION: 6 ppm/V Typ.
• WIDE SUPPLY RANGE: ±13.5 V to ±22.0 V
• HERMETIC 14-PIN CERAMIC DIP
• MILITARY PROCESSING OPTION
• PRECISION A/D and D/A CONVERTERS
• TRANSDUCER EXCITATION
• ACCURATE COMPARATOR THRESHOLD
REFERENCE
• HIGH RESOLUTION SERVO SYSTEMS
• DIGITAL VOLTMETERS
• HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
DESCRIPTION
VRE105 Series Precision Voltage References
provide ultrastable +5.000 V (VRE105) and
±5.000 V (VRE107) outputs with ±0.4 mV initial
accuracy and temperature coefficient as low as
0.6 ppm/°C over the full military temperature
range. This impovement in accuracy is made
possible by a unique, proprietary multipoint laser
compensation technique developed by Thaler
Corporation. Significant improvements have been
made in other performance parameters as well,
including initial accuracy, warm-up drift, line
regulation, and long-term stability, making the
VRE105 series the most accurate and stable 5V
references available.
SELECTION GUIDE
Type
VRE105C
VRE105CA
VRE105M
VRE105MA
VRE107C
VRE107CA
VRE107M
VRE107MA
Output Temperature
Operating Range
+5V -25°C to +85°C
+5V -25°C to +85°C
+5V -55°C to +125°C
+5V -55°C to +125°C
±5V -25°C to +85°C
±5V -25°C to +85°C
±5V -55°C to +125°C
±5V -55°C to +125°C
Max. Volt
Deviation
0.4mV
0.2mV
0.6mV
0.3mV
0.4mV
0.2mV
0.6mV
0.3mV
VRE105 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to
+125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for
maximum long-term stablity. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make these references ideal for precision applications such as A/D
and D/A converters, high accuracy test and measurement instrumentation, and tranducer excitation.
VRE105DS REV. C SEPT 1994
4-32