UDM35 Datasheet, PDF (1/11 Pages) List of Unclassifed Manufacturers – Digital Panel Meters Modular Indicator and Controller | |||
|
Digital Panel Meters
Modular Indicator and Controller
Type UDM35
⢠Front protection degree: IP67, NEMA4x
⢠Multi-input modular instrument 3 1/2 dgt LED
⢠0.1% RDG basic accuracy
⢠TRMS AC current and voltage measurements
⢠AC/DC current measurements: selectable full scales
(200µA to 5A)
⢠AC/DC voltage measurements: selectable full scales
(200mV to 500V)
⢠°C or °F temperature measurements
(Pt100-250-500-1000, Ni100, TC J-K-S-T-E)
⢠Resistance measurements: selectable full scales
(20⦠to 20kâ¦)
⢠Up to 4 independent alarm set-points (optional)
⢠20mA/10VDC analog output (optional)
⢠Serial port RS485 or RS232 (optional)
⢠MODBUS, JBUS communication protocol
Product Description
µp-based digital panel
meter, 3 1/2 dgt LED indica-
tor, for current, voltage, tem-
perature and resistance
measurements. Measuring
ranges and functions easily
programmable from the key-
pad or from the PC by
means of optional UdmSoft
software. UDM35 includes
storage min-max functions
and double level protection
password. Housing for
panel mounting with front
protection degree: IP67,
NEMA4x.
Type Selection
How to order UDM35 XXX XX XX X XX
Model
Slot A
Slot B
Slot C
Slot D
Options
How to order UdmSoft-kit
UdmSoft-kit: software plus âUCOM1â communication cable for
programming UDM35 by means of PC.
Slot A (measuring inputs)
Slot B (communication)
Slot C (communication and alarm) Slot D (power supply)
LSX:
LSE/
LSF:
HSX:
TRX:
signal inputs:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
signal inputs + AUX:
0.2-2-20mA DC/AC;
0.2-2-20V DC/AC
signal inputs:
0.2-2-5A DC/AC;
20-200-500V DC/AC
signal inputs: TC tem-
perature probes (J-K-S-
T-E, Pt100-250-500-
1000) and resistance
(0.02-0.2-2-20kâ¦)
XX: None
SX: Serial port RS485
SY: Serial port RS232
AV (*): Single analogue output,
0 to 20mA DC and
0 to 10V DC
(*): The two analogue
outputs cannot be
used at the same
time. It is possible to
plug in only one
module by instru-
ment.
XX: None
R1: single relay output,
(AC1-8AAC, 250VAC)
R2: Dual relay output,
(AC1-8AAC, 250VAC)
R4: Dual relay output (AC1-
8AAC, 250VAC) + dual
open collector output
(NPN, 100mA)
R5: 4 relay outputs
(AC1-5AAC, 250VAC)
AV(*): Single analogue output,
0 to 20mA DC and
0 to 10V DC
H: 90 to 260V AC/DC
L: 18 to 60V AC/DC
Options
XX: None
TX: Tropicalization
Input Specifications
Analogue inputs
BQ LSX module
BQ LSE/BQ LSF module
BQ HSX module
BQ TRX module
BQ TRX module
Digital inputs
Number of inputs
Use
Channels and variable
1, mA and V DC/AC
1, mA and V DC/AC + AUX
1, A and V DC/AC
1, temperature
1, resistance
Incl. in the measuring module
1 (voltage-free)
key-pad lock
Display hold
Reset of latch alarms
Contact reading signal
Close contact resistance
Open contact resistance
Insulation
Accuracy (display, RS485)
BQ xxx: <0.1mA, <3,5V DC
BQ LSE/BQ LSF: <2.5mA,
<14V DC
Max 1kâ¦
Min 500kâ¦
Non-insulated
See table âMeasuring
accuracyâ, temperature drifts
and minimum-maximum
indicationsâ
Specifications are subject to change without notice UDM35DS 040706