TPMPU50 Datasheet, PDF (1/2 Pages) Total Power International – 50W Desk Top Switching Power Supplies For Medical Equipment.
TOTAL POWER INT'L
TPMPU50 SERIES
50W Desk Top Switching Power Supplies For Medical Equipment.
Description:
The TPMPU50 series of AC/DC switching mode power supplies
provide 50 Watts of continuous output power. All supplies are UL
94V-0 compliant, include IEC-320-C14 input for worldwide
applications. All models meet FCC Part-15 class B and CISPR -11
EN55011 class B emission Limits and are designed to comply with
UL, C-UL, CB and CE requirements. All units are 100% burned in
and tested.
Features:
+ Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
+ IEC-320-C14 Input Inlet
+ Single to Triple Output
+ Output Voltage Available From 2VDC Thru 50VDC
+ Optional Output Connector (See appendix)
+ Input Surge Current, Over Voltage And Over Load protection
+ Splash proof
+ Two Year Warranty
Electrical Characteristics:
Safety Approvals :
EN 60601-1
C
US
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
90
264 VAC
Fin Input Frequency
47
63 Hz
Wo Output Power Range
Vin=90 to 264VAC
0
50
W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
1.35 A
Iih Input Current (High Line) Io=Full load, Vin=230 VAC
0.7 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Io=Full load, 25°c, Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
12 15
A
26 30
A
Eff Efficiency
Io=Full Load, Vin=230VAC
75 83 88
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
37
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
110
150 %
Ttr Transient Response
Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
16
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1.5 2
S
Vrn Ripple & Noise (Pea k to Peak) Full Load, Vin=90VAC
12
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.1 mA
Tc Temperature Coefficient
Environmental :
All output
-0.04
0.04 %/°c
Sym.
Parameter
Test Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
Pd Derate linearly from 100% load at 50°c to 50% load at 70°c
Safety Specifications:
Min. Typ. Max.
0
70
-40
85
5
95
Unit
°c
°c
%
Sym.
Parameter
Dielectric Withstanding Voltage
Vps
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-11
FCC EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
5656
VDC
2121
50
B
B
VDC
MW
CLASS
CLASS
TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com