English
Language : 

TFS110K1 Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Filter
tfs110k1.doc
version 1.0
05.01.02
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 110 K1 1/4
______________________________________________________________________________________________________
Measurement Condition
Ambient Temperature:
23 °C
Input Power Level:
0 dBm
Terminating impedances:
Input:
700 Ω || -13,7 pF
Output:
700 Ω || -11,6 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 K1 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be
reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating
temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. Value
Limit
______________________________________________________________________________________________________
Insertion Loss
ae = amin
-
max. 9 dB
(Reference level)
______________________________________________________________________________________________________
Nominal frequency
fN
110,6 MHz
______________________________________________________________________________________________________
Relative attenuation
arel
fN - 65 kHz ... fN + 65 kHz
fN ± 65 kHz ... fN ± 82,5 kHz
-
max. 1 dB
-
max. 1,5 dB
fN ± 400 kHz ... fN ± 800 kHz
-
min. 22 dB
fN ± 800 kHz ... fN ± 1,6 MHz
-
min. 27 dB
fN ± 1,6MHz ... fN ± 10 MHz
-
min. 35 dB
fN ± 10 MHz ... fN ± 25 MHz
-
min. 45 dB
______________________________________________________________________________________________________
Group delay
GD
Ripple fN ± 80 kHz
300
ns
max 500
ns
_____________________________________________________________________________________________________
Input power level
-
max. + 10 dBm
______________________________________________________________________________________________________
Permissible DC voltage
-
max. 10 V
______________________________________________________________________________________________________
Operating Temperature Range
- 25 °C ... + 85 °C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.