English
Language : 

SLT-3X Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – SPECIFICATION CONTROL DRAWING
SPECIFICATION CONTROL DRAWING
Product Revisions
Component Dimensions
Cable Dimensions
Part Name
L
B
C
E
F
G
H
D
max
min
min
max
min ±0.5(0.020) ±0.5(0.020) max
SLT-3X
B 17.3
2.7
3.1
3.1
1.4
(0.681) (0.106) (0.122) (0.122) (0.055)
7
(0.276)
6
(0.236)
2.7
(0.106)
SLT-5X
B 17.3
4.4
5.0
5.0
2.5
(0.681) (0.173) (0.197) (0.197) (0.098)
7
(0.276)
6
(0.236)
4.4
(0.173)
SLT-6X
C 20.0
5.9
6.4
6.4
3.2
(0.787) (0.2.32) (0.252) (0.252) (0.126)
7
(0.276)
6
(0.236)
5.9
(0.2.32)
SLT-7X
C 20.0
7.1
7.6
7.6
4.1
(0.787) (0.280) (0.299) (0.299) (0.161)
7
(0.276)
6
(0.236)
7.1
(0.280)
SLT-12X
E 31.5
10.8
11.6
11.6
7.3
(1.240) (0.425) (0.457) (0.457) (0.287)
9.5
(0.374)
8.5
(0.335)
10.8
(0.425)
SLT-14X
H 31.2
13.3
13.8
13.3
8.1
(1.228) (0.524) (0.543) (0.524) (0.319)
7
(0.276)
6
(0.236)
8.9
(0.350)
MATERIAL
1. INSULATION SLEEVE: Heat-shrinkable, radiation cross-linked modified polyvinylidene fluoride. Transparent clear.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Cd18 per ANSI J-STD-006.
FLUX: TYPE ROL1 per ANSI J-STD-004. Color: red.
3. MELTABLE SEALING RING: Thermally stabilized thermoplastic. Color: blue.
4. MELTABLE SEALING RING: Thermally stabilized thermoplastic. Color: clear.
APPLICATION
1. This controlled soldering device is designed for termination of a tin or silver plated copper shield on a cable having an
insulation rated for at least +105°C.
2. Temperature range: -55°C to +125°C.
3. For application tooling contact your local Raychem technical service.
For best results, prepare the cable as shown:
*A trademark of Raychem Corporation.
Raychem
THERMOFIT
DEVICES
Raychem Corporation
300 Constitution Drive
Menlo Park, CA 94025 USA
TITLE:
SOLDERSLEEVE*DEVICE
SHIELD TERMINATION
LOW TEMPERATURE
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE IN BETWEEN BRACKETS.
DOCUMENT NO.: SLT-YX/1YX
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Raychem reserves the right to amend this
drawing at any time. Users should evaluate
the suitability of the product for their
application.
DCR NUMBER:
D981081
REPLACES:
slt3x, slt5x, slt6x, slt7x,
slt12x & slt14x
DRAWN BY:
R. MAPALO
DATE:
07-06-98
REV.:
SEE TABLE
DOC ISSUE: SCALE:
1
NONE
SIZE:
A
SHEET:
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision