CURRENT DERATING CURVE
4
3
2
1
0
20
40
60
80
Ambient Temperature [˚ûC]
Max Load Current vs. Temperature
.45
.68 (11.4)
(17.3)
.80
(20.3)
.60
(15.2)
.10
(2.5)
.70
.87 (17.8)
(22.1)
S3
Package
.025 x .025
TERMINAL PIN
2
3 + (4 PLACES)
BOTTOM
VIEW
1
4
.70
(17.8)
.80
(20.3)
1.20
(30.5)
S30
Package
.80
(20.3)
.60
(15.2)
.025 x .025
TERMINAL PIN
2
3 + (4 PLACES)
BOTTOM
VIEW
1
4
.10
(2.5)
.70
(17.8)
.80
(20.3)
1.45
(36.8)
All dimensions are in inches (millimeters)
APPROVALS
UL E116949
CSA LR81689
VDE 10114 UG
FastFax Document No. 117
SERIES 3
Rev. 042302
PAGE 1 OF 1
Series 3
3 Amp • 120, 240 Vac • AC Output
• Compact for High
Density PCB M ount
• Small Footprint
• UL, CSA, VDE Approved
work (S3 types), Series 3 is an ideal
replacement for power reed relays in
microprocessor or computer-based logic
level systems. Designed for long, reli-
able service in a multitude of demand-
ing industrial environments.
These solid state relays combine small
size and high ratings in a PC-board-
mounted SPST-NO design. Available
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
with (S30 types) or without snubber net-
MODEL NO.
INPUT SPECIFICATIONS ➀
Control Voltage Range
S312
S3012A
3.5-8 Vdc
S322
S3022A
3.5-8 Vdc
Nominal Input Impedance
200 Ohm
200 Ohm
Typical Input Current @ 5 Vdc
20 mAdc
20 mAdc
Must Turn On Voltage
3.5 Vdc
3.5 Vdc
Must Turn Off Voltage
OUTPUT SPECIFICATIONS ➀
Operating Voltage Range (47-63 Hz)
1.0 Vdc
20-140 Vrms
1.0 Vdc
40-280 Vrms
Load Current Range (Arms)
.15-3.0
.15-3.0 .15-3.0
.15-3.0
Transient Over-Voltage
600 Vpk
600 Vpk
Max. Surge Current, (16.6ms)
Min. Off-State dv/dt @ Max. Rated Voltage ➂
55 Apk
200 V/µsec
55 Apk
200 V/µsec
Max.Off-State Leakage @ Rated Voltage 1.0 mA
4.0 mA 1.0 mA
4.0 mA
Max. On-State Voltage Drop @ Rated Current
1.5 Vpk
1.5 Vpk
Max.Turn-On Time
1/2 cycle
1/2 cycle
Max. Turn-Off TIme
1/2 cycle
1/2 cycle
Power Factor (Min.) WIth Max. Load
0.5
0.5
GENERAL SPECIFICATIONS
Dielectric Strength ➁
Insulation Resistance (Min.) @ 500 Vdc ➁
4000 Vrms
109 Ohm
Max. Capacitance
8.0 pF
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-30 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
0.6 oz. (0.8 g)
Encapsulation:
Thermally Conductive Epoxy
GENERAL NOTES
©2002 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25˚C unless otherwise specified.
➁ Dielectric and insulation resistance are measured between input and output.
➂ Off-State dv/dt test method per EIA/NARM standard RS-443.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506