Series RPC
Solid State Proportional Controller
15-40 Amp, 120/240/480 Vac Output
• Uses Potentiometer for
Economical Pow er Control
• Industry Standard Package
The RPC series proportional controllers
provide a cost effective method of con-
trolling power in many different appli-
cations such as heaters, universal
motors or incandescent lamps. A cus-
tomer provided potentiometer is all that
is required for control. All modules are
supplied with KS100 protective cover.
8
MODEL
NUMBERS
OUTPUT SPECIFICATIONS ➀
RPC1215 RPC1225 RPC1240 RPC2415 RPC2425 RPC2440 RPC4815 RPC4825 RPC4840
Operating Voltage (47-63 Hz) [Vac]
Max. Load Current ➂ [Arms]
90-130 90-130 90-130
15
25
40
Min. Load Current, [mArms]
70
80
90
Transient Overvoltage [Vpk]
400
400
400
Max. Surge Current, (16.6ms) [Apk]
150
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6
1.6
1.6
Thermal Resistance Junction to Case [RθJC]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
1.48
1.02
.63
94
260 1620
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10
10
10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500
500
500
Max. Turn-On Time ➃ [msec]
Max. Turn-Off Time [msec]
Power Factor (Min.) with Max. Load
0.6
0.6
0.6
Snubber (Internal)
yes
yes
yes
200-240 200-240 200-240 400-480 400-480 400-480
15
25
40
15
25
40
70
80
90
70
80
90
600
600
600
1200 1200 1200
150
250
625
150
250
625
1.6
1.6
1.6
1.6
1.6
1.6
1.48
1.02
.63
1.48
1.02
.63
94
260 1620
94
260 1620
7
7
7
3
3
3
500
500
500
500
500
500
0.6
0.6
0.6
yes
yes
yes
0.6
0.6
0.6
no
no
no
INPUT SPECIFICATIONS ➀
Resistor, Variable [Ohms] ➃
150K (1W) 150K (1W) 150K (1W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W)
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Potentiometer should be selected with regards to line voltage isolation.
©2002 CRYDOM CORP, Specifications subject to change without notice.
WARNING
Control to load is not isolated, excercise care in handling the
RPC products to avoid the risk of electric shock.
FastFax Document No. 205
SERIES RPC.
Rev. 041902
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506