English
Language : 

RMB962 Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – miniature relays
RMB962
miniature relays
1
BISTABLE
2-COILS
Contact data
Number and type of contacts
Contact material
Max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
Coil data
Rated voltage
Operating range of supply voltage
Duration of supply voltage pulse
Insulation
Insulation category
Insulation rated voltage
Insulation max. voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• between coil and contacts
• contact clearance
Contact - coil distance
• clearance
• creepage
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
Cover protection category
Environmental protection
Vibration resistance
Solder bath temperature
Soldering time
• Height 15 mm • IP 67
• For PCB
• Insulation 4 kV / 8 mm
• High switching capacity, low power consumption
• Bistable relays with two coils • DC coils
• Terminals raster: type A - 3,2 mm for version 1 C/O,
type A - 5,0 mm for version 1 NO ❶
• Recognitions, certifications, directives: RoHS,
AC/DC
AC1
AC1
1 C/O, 1 NO
AgSnO2, AgCdO, AgCdO/Au 3,5 µm
400 V / 300 V
24 V AgSnO2, 24 V AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
8 A / 250 V AC
100 mA AgSnO2, 100 mA AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
10 A
8A
2 000 VA
2,4 W AgSnO2, 2,4 W AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
≤ 100 mΩ
AC1 3 600 cycles/hour
20 000 cycles/hour
DC 3...24 V ❷
see Table 1
min. 10 ms;
max. 5 s
C250
250 V AC
400 V AC
4 000 V AC
III
PN-EN 60664-1
3
4 000 V AC
1 000 V AC
≥ 8 mm
≥ 8 mm
10 ms
7 ms
> 105
8 A, 250 V AC
> 105
5 A, 250 V AC
> 3 x 107
29 x 10 x 15 mm
10 g
-40...+80 oC
-40...+70 oC
IP 67
RTII
PN-EN 116000-3
10 g 10...100 Hz
max. 270 oC
max. 5 s
The data in bold type pertain to the standard versions of the relays.
Note: At IP 67 waterproof version it is recommended that the vent pin is removed after soldering and washing process.
❶ Relays with other rasters available - contact Relpol S.A.
❷ Supply of bistable relays RMB962 - see page 2
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl