English
Language : 

PMR209 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – RC unit, class X2, metallized paper with integrated resistor
PMR209
• RC unit, class X2, metallized paper with integrated resistor
• 0.047 – 0.47 µF, 22 – 470 Ω, 250 VAC, +85 °C
• Small dimensions
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Self-extinguishing encapsulation.
• Good resistance to ionisation due
to impregnated dielectric.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous operation.
TYPICAL APPLICATIONS
CONSTRUCTION
RC unit for use in DC and AC applications
for:
– contact protection
– interference suppression of contacts
– transient suppression
Single layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL 94V-
0. The resistance in the metal layer is
utilized as series resistance, integrated
resistor.
TECHNICAL DATA
L
B
p ± 0.5
∅d
Rated voltage
250 VAC 50/60 Hz, 630 VDC
Capacitance range
Capacitance tolerance
Resistance range
Resistance tolerance
0.047 – 0.47 µF
± 20%
22 – 470 Ω
± 30%
R
C
Peak pulse voltage
Temperature range
Climatic category
Approvals
Series resistance
1000 V
–40 to +85°C
40/085/56/B
S, N, D, FI, VDE, SEV, UL
The series resistance is defined at 1 kHz for RC ≥ 50 µs
and at 100 kHz for RC < 50 µs.
d = 0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
l: standard: 30 +5/-0 mm (code R30)
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request.
Insulation resistance
≥ 3000 MΩ for C ≤ 0.33 µF
≥ 1000 s for C > 0.33 µF
Measured at 500 VDC after 60 s, +23°C
Pmax
W
0.5
1 234
Pulse current
Max 12 A repetitive. Max 20 A peak for occasional transients.
Test voltage between
terminals
In DC applications
Power ratings
The 100% screening factory test is carried out at 1800
VDC. The voltage level is selected to meet the requirements
in applicable equipment standards. All electrical
characteristics are checked after the test.
Recommended voltage ≤ 630 VDC.
The average losses may reach 0.5 W provided the surface
temperature does not exceed + 85°C. For max. permitted
power dissipation vs temperature, see derating curves.
0
Tamb
40
50
60
70
80 85 °C
Maximum allowable power dissipation vs
ambient temperature and case sizes.
Curve
Dimensions
1
B = 7.3
2
B = 7.6
3
B = 11.3
4
B = 15.3
ENVIRONMENTAL TEST DATA
Vibration
Bump
IEC 60068-2-6, Test Fc
IEC 60068-2-29, Test Eb
3 directions at 2 hour each
No visible damage, No open or short circuit
10 – 500 Hz at 0.75 mm or 98 m/s2
4000 bumps at 390 m/s2
No visible damage, No open or short circuit
Solderability
IEC 60068-2-20, Test Ta
Active flammability EN 132400
Solder globule method
Wetting time for d ≤ 0.8 < 1 s
for d > 0.8 < 1.5 s
Passive flammability IEC 60384-14 (1993), EN 132400
Humidity
IEC 60068-2-3, Test Ca
+40°C and 90 – 95% R.H.
56 days
196