English
Language : 

PMR205 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – RC unit, metallized paper with integrated resistor
PMR205
• RC unit, metallized paper with integrated resistor
• 0.1 – 1.0 µF, 22 - 680 Ω, 125 VAC, +85 °C
• Small dimensions
• High dU/dt capability.
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• Self-extinguishing encapsulation.
• Good resistance to ionisation due
to impregnated dielectric.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous operation.
TYPICAL APPLICATIONS
CONSTRUCTION
RC unit for use in DC and AC applications
for:
– contact protection
– interference suppression of contacts
– transient suppression
Single layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0. The resistance in the metal layer is
utilized as series resistance, integrated
resistor.
TECHNICAL DATA
Rated voltage
Capacitance range
Capacitance tolerance
Resistance range
Resistance tolerance
Peak pulse voltage
Temperature range
Climatic category
Series resistance
Insulation resistance
Power ratings
250 VDC, 125 VAC
0.1–1.0 µF
± 20%
22 – 680 Ω
± 30%
375 V
–40 to +85°C
40/085/56/B
The series resistance is defined at 1 kHz for RC ≥ 50 µs
and at 100 kHz for RC < 50 µs.
≥ 3000 MΩ for C ≤ 0.33 µF
≥ 1000 s for C > 0.33 µF
Measured at 100 VDC after 60 s, +23°C
The average losses may reach 0.5 W provided the
surface temperature does not exceed + 85°C. For
maximum permitted power dissipation v temperature,
see derating curves.
Curve
1
2
2
3
4
5
Dimensions
B = 5.2
B = 7.3
B = 7.8
B = 7.6
B = 9.0
B = 11.3
L
B
p ± 0.5
∅ 0.8
R
C
l: standard: 30 +5/-0 mm (code R30)
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request.
Pmax
W
1
0.5
2 3 45
0
Tamb
40
50
60
70
80 85 °C
Maximum allowable power dissipation vs
ambient temperature and case sizes.
ENVIRONMENTAL TEST DATA
Vibration
IEC 60068-2-6, Test Fc 3 directions at 2 hour each
10 – 500 Hz at 0.75 mm or 98 m/s2
Bump
IEC 60068-2-29, Test Eb 4000 bumps at 390 m/s2
Solderability IEC 60068-2-20, Test Ta Solder globule method
Humidity
IEC 60068-2-3, Test Ca +40°C and 90 – 95% R.H.
No visible damage, No open or short circuit
No visible damage, No open or short circuit
Wetting time < 1 s
56 days
194