PME294 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – EMI suppressor, class Y1, metallized paper
PME294
• EMI suppressor, class Y1, metallized paper
• Safety capacitor, ceramic replacement
• 470 – 4700 pF, 440 VAC, +115 °C, test voltage 4000 VAC 60 s
• Self-extinguishing encapsulation. The
material is recognized according to
UL 94 V-0.
• Very precise positioning of the leads in
relation to the case giving efficient
utilisation of PC board space.
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Good resistance to ionisation due to
impregnated dielectric.
• The capacitors meet the most stringent
IEC humidity class, 56 days.
• The impregnated paper ensures excellent
stability giving outstanding reliability
properties, especially in applications
having continuous operation.
TYPICAL APPLICATIONS
CONSTRUCTION
Safety capacitor for bridging of double or
reinforced insulation applications requiring
voltage test up to 4000 VAC 60 seconds.
PME294 can be left in place during this test.
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing material
meeting the requirements of UL 94V-0.
TECHNICAL DATA
L
B
p ± 0.3
∅ 0.8
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
Dissipation factor tanδ
Insulation resistance
Resonance frequency
In DC applications
Test voltage between
terminals
440 VAC 50/60 Hz
470 – 4700 pF
± 20%
–40 to +115 °C
40/115/56/B
S, N, D, FI, VDE, SEV, IMQ, UL, CSA
≤ 1.3 % at 1 kHz
≥ 12000 MΩ
Measured at 500 VDC after 60 s, +23°C
Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Recommended voltage: ≤ 1500 VDC
l = standard : 30 +5/-0 mm
option : short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
dB
Attenuation
70
60
50
40
4700 pF
1500 pF
470 pF
30
20
10
f
0
1
3 5 10
30
100 200 MHz
Suppression versus frequency. Typical values.
The 100% screening factory test is carried out at
4000 VAC, 50 Hz, 2 s. The voltage level is selected to
meet the requirements in applicable equipment standards.
All electrical characteristics are checked after the test.
Vibration
Bump
Solderability
Active flammability
Passive flammability
Humidity
ENVIRONMENTAL TEST DATA
IEC 60068-2-6
Test Fc
3 directions at 2 hour each
10 – 500 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
IEC 60068-2-29
Test Eb
4000 bumps at 390 m/s2
No visible damage
No open or short circuit
IEC 60068-2-20
Test Ta
Solder globule method
Wetting time < 1 s
EN 132400
IEC 60384-14 (1993)
EN 132400
IEC 60068-2-3
Test Ca
+40°C and 90 – 95% R.H.
56 days