English
Language : 

PME285 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – EMI suppressor, class X2, metallized paper
PME285
• EMI suppressor, class X2, metallized paper
• 0.001 – 0.1 µF, 275 VAC, +110 °C
• The highest possible safety regarding
active and passive flammability.
• Self-extinguishing encapsulation. The
material is recognized according to
UL 94 V-0.
• Very precise positioning of leads in
relation to the case giving efficient
utilisation of PC board space.
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Good resistance to ionisation due to
impregnated dielectric.
• The capacitors meet the most stringent
IEC humidity class, 56 days.
• The impregnated paper ensures excellent
stability giving outstanding reliability
properties, especially in applications
having continuous operation.
TYPICAL APPLICATIONS
CONSTRUCTION
The capacitors are intended for use as
Multi-layer metallized paper. Encapsulated
interference suppressors in X2, across-the- and impregnated in self-extinguishing material
line, antenna-coupling and line-by-pass. meeting the requirements of UL 94V-0.
TECHNICAL DATA
L
B
p ± 0.3
∅d
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
Dissipation factor tanδ
Insulation resistance
Resonance frequency
In DC applications
Test voltage between
terminals
275 VAC 50/60 Hz
0.001 – 0.1 µF
± 20%
–40 to +110°C
40/110/56/B
S, N, D, FI, VDE, SEV, IMQ, UL, CSA
≤ 1.3 % at 1 kHz
≥ 12000 MΩ
Measured at 500 VDC after 60 s, +23°C
Tabulated self-resonance frequencies f0 refer to 5 mm
lead lengths.
Recommended voltage: ≤ 630 VDC
The 100% screening factory test is carried out at
2150 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards.
d = 0.6 for p = 10.2
0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
l = standard : 30 +5/-0 mm
option : short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
Vibration
Bump
ENVIRONMENTAL TEST DATA
IEC 60068-2-6, Test Fc 3 directions at 2 hour each
10 – 500 Hz at 0.75 mm or 98 m/s2
IEC 60068-2-29, Test Eb 4000 bumps at 390 m/s2
Solderability
Active flammability
Passive flammability
Humidity
IEC 60068-2-20, Test Ta Solder globule method
EN 132400
IEC 60384-14(1993)
EN 132400
IEC 60068-2-3, Test Ca +40°C and 90 – 95% R.H.
No visible damage
No open or short circuit
No visible damage
No open or short circuit
Wetting time < 1 s
56 days
170