|
PME264 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – EMI suppressor, class X2, metallized paper | |||
|
PME264
⢠EMI suppressor, class X2, metallized paper
⢠0.001 â 0.1 µF, 660 VAC, +85 °C
⢠Self-extinguishing encapsulation.
⢠High dU/dt capability.
⢠Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
⢠Good resistance to ionisation due to
impregnated dielectric.
⢠The capacitors meet the most
stringent IEC humidity class, 56 days.
⢠The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
TYPICAL APPLICATIONS
High AC and DC voltage applications,
such as
â commutator capacitor in converters
â high voltage DC-capacitor in TV sets
â ignition circuits.
CONSTRUCTION
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing material
meeting the requirements of UL 94V-0.
L
B
p ± 0.5
â
d
TECHNICAL DATA
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
Dissipation factor tanδ
Insulation resistance
Test voltage between terminals
660 VAC 50/60 Hz
1500 VDC
(1600 VDC, + 50°C)
0.001 â 0.1 µF
± 20%
â40 to +85°C
40/085/56/B
S, UL
⤠1.3 % at 1 kHz
⥠12000 Mâ¦
Measured at 500 VDC after 60 s, +23°C
The 100% screening factory test is carried
out at 3000 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards.
d = 0.8 for p = 15.2 and 20.3
1.0 for p = 25.4
l = standard: 30 +5/-0 mm
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
ENVIRONMENTAL TEST DATA
Vibration
Bump
Solderability
IEC 60068-2-6
Test Fc
IEC 60068-2-29
Test Eb
IEC 60068-2-20
Test Ta
Active flammability
Passive flammability
Humidity
EN 132400
IEC 60384-14 (1993)
EN 132400
IEC 60068-2-3
Test Ca
3 directions at 2 hour each,
No visible damage
10 â 500 Hz at 0.75 mm or 98 m/s2 No open or short circuit
4000 bumps at 390 m/s2
No visible damage
No open or short circuit
Solder globule method
Wetting time
for d ⤠0.8 < 1 s
for d > 0.8 < 1.5 s
+40°C and 90 â 95% R.H.
56 days
160
|
▷ |