|
PHE844 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – EMI suppressor, class X1, metallized polypropylene | |||
|
PHE844
⢠EMI suppressor, class X1, metallized polypropylene
⢠0.1 â 2.2 µF, 440 VAC/480VAC, +105°C
⢠New, small dimensions
TYPICAL APPLICATIONS
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
CONSTRUCTION
Metallized polypropylene winding,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 Vâ0.
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category
Approvals
Dissipation factor
Test voltage between
terminals
Resonance frequency
Insulation resistance
In DC application
TECHNICAL DATA
440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
0.1 â 2.2 µF
± 20% standard, ± 10% option
â40 to +105°C
40/105/56/B
ENEC, UL, CSA
Maximum values at +23°C
C ⤠0.1 µF 0.1µF < C ⤠1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
â
C > 1 µF
0.1%
0.8%
â
The 100% screening factory test is carried out at 2700
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
C ⤠0.33 µF: ⥠30 000 Mâ¦
C > 0.33 µF: ⥠10 000 s
Recommended voltage: â¤1000VDC
L
B
H
0.5
p
â
d
b
l
p
d
std l max l b
22.5 ± 0.4 0.8
27.5 ± 0.4 0.8
37.5 ± 0.4 1.0
6 30 ±0.4
6 30 ±0.4
6 30 ±0.4
Tolerance in lead length
< 30 mm
+0
â1
mm
⥠30 mm
+5
â0
mm
Endurance
Vibration
Bump
Change of temperature
Active flammability
Passive flammability
Humidity
ENVIRONMENTAL TEST DATA
IEC 60384â14
1.25 x U VAC 50 Hz,
R
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
IEC 60068â2â6
Test Fc
3 directions at 2 hours each,
10â55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
IEC 60068â2â29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
IEC 60068â2â14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
EN 132400
IEC 60384-14 (1993)
EN 132400
UL1414
Enclosure material of
UL94Vâ0 flammability class
IEC 60068-2-3
Test Ca
+40°C and
90 â 95% R.H.
56 days
154
|
▷ |