PHE843 Datasheet, PDF (1/2 Pages) List of Unclassifed Manufacturers – EMI suppressor, class X2, metallized polypropylene 0.01-6.8 uF, 275/280 VAC, +105C For replacement, see PHE840M
PHE843
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 6.8 µF, 275/280 VAC, +105°C
• For replacement, see PHE840M
TYPICAL APPLICATIONS
CONSTRUCTION
For worldwide use as electromagnetic
Metallized polypropylene winding,
interference suppressor in all X2 and across- encapsulated in self-extinguishing material
the-line applications.
meeting the requirements of UL 94 V–0.
TECHNICAL DATA
Rated voltage
275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, CSA)
Capacitance range
0.01 – 6.8 µF
Capacitance tolerance
± 20% standard, ± 10% option
Temperature range
–40 to +105°C
Climatic category
n Approvals
sig Dissipation factor tanδ
new d0eM Test voltage between
r 4 terminals
ot foPHE8 Resonance frequency
N use Insulation resistance
40/105/56/B
S, UL, CSA
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
The 100% screening factory test is carried out at
2200 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Tabulated self-resonance frequencies f0 refer to
5 mm lead length.
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC applications
Recommended voltage: ≤ 630 VDC
L
B
H
0.5
p
∅d
b
l
p
d
std l max l b
10.0 ± 0.4 0.6 17
15.0 ± 0.4 0.8 17
22.5 ± 0.4 0.8
6
27.5 ± 0.4 0.8
6
37.5 ± 0.5 1.0
6
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.7
Tolerance in lead length
<
30
mm
+0
–1
mm
≥ 30 mm +5 mm
–0
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN 132400
Passive flammability
IEC 60384-14 (1993)
EN 132400
UL1414
Enclosure material of
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
152