English
Language : 

PHE840M Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – New, small dimensions including low profile capacitors
PHE840M
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10.0 µF, 275/280 VAC, +105°C
• New, small dimensions including low profile capacitors
• Replaces PHE843
TYPICAL APPLICATIONS
CONSTRUCTION
L
B
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
Metallized polypropylene film encapsulated
with selfextinguishing epoxy resin in a box of
material recognized to UL 94 V–0.
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category
Approvals
Dissipation factor
TECHNICAL DATA
275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, CSA)
0.01 – 10.0 µF
± 20% standard, ± 10% option, ± 5% on request
–55 to +105°C
55/105/56/B
ENEC, UL, CSA
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
H
0.5
p
∅d
b
l
p
d
std l max l b
7.5 ± 0.4 0.6 17
10.0 ± 0.4 0.6 17
15.0 ± 0.4 0.8 17
22.5 ± 0.4 0.8
6
27.5 ± 0.4 0.8
6
37.5 ± 0.5 1.0
6
20 ±0.4
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.7
Tolerance in lead length
< 30 mm +0 mm
–1
≥ 30 mm
+5
–0
mm
Test voltage between
terminals
The 100% screening factory test is carried
out at 2200 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards. All
electrical characteristics are checked
after the test.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC applications
Maximum voltage 630 VDC
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
Vibration
IEC 60068–2–6
Test Fc
Bump
IEC 60068–2–29
Test Eb
Change of temperature IEC 60068–2–14
Test Na
Active flammability
EN 132400
Passive flammability
IEC 60384-14 (1993)
EN 132400
UL1414
Humidity
IEC 60068-2-3
Test Ca
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Upper and lower rated
temperature 5 cycles
No visible damage
Enclosure material of
UL94V–0 flammability class
+40°C and
90 – 95% R.H.
56 days
144