English
Language : 

PHE840E Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – EMI suppressor, class X2, metallized polypropylene(0.01-10 uF, 300 VAC, +105C)
PHE840E
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10 µF, 300 VAC, +105°C
TYPICAL APPLICATIONS
CONSTRUCTION
For worldwide use as electromagnetic
Metallized polypropylene winding,
interference suppressor in all X2 and across- encapsulated in self-extinguishing material
the-line applications.
meeting the requirements of UL 94 V–0.
Rated voltage
TECHNICAL DATA
300 VAC 50/60 Hz
Capacitance range
0.01 – 10 µF
Capacitance tolerance
± 20% standard, ± 10% option
Temperature range
–55 to +105°C
Climatic category
55/105/56/B
Approvals
ENEC, UL, CSA
Dissipation factor tanδ
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz 0.1%
0.1%
10 kHz 0.2%
0.4%
100 kHz 0.6%
–
C > 1 µF
0.1%
0.8%
–
Test voltage between
terminals
The 100% screening factory test is carried out at
2200 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency
Tabulated self-resonance frequencies f0 refer to
5 mm lead length.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 ΩF
In DC applications
Recommended voltage ≤ 760 VDC
L
B
H
0.5
p
∅d
b
l
P
d std l max l b
10.0 ± 0.4 0.6 17
15.0 ± 0.4 0.8 17
22.5 ± 0.4 0.8
6
27.5 ± 0.4 0.8
6
37.5 ± 0.5 1.0
6
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.4
30 ±0.7
Tolerance in lead length
< 30 mm +0 mm
–1
≥ 30 mm
+5
–0
mm
DATA SHEET PHE840E
DATA SHEET MMK
Specifications subject to change without
notice.
© Evox Rifa 05/2003
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN 132400
Passive flammability
IEC 60384-14 (1993)
EN 132400
UL1414
Enclosure material of
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
141